background image

Warranty and Assistance

The

 

05103-LC AND 05305-LC R.M. YOUNG WIND MONITOR FOR

METDATA1 

is warranted by CAMPBELL SCIENTIFIC, INC. to be free from

defects in materials and workmanship under normal use and service for twelve
(12) months from date of shipment unless specified otherwise.  Batteries have
no warranty.  CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty
is limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s
option) defective products.  The customer shall assume all costs of removing,
reinstalling, and shipping defective products to CAMPBELL SCIENTIFIC,
INC.  CAMPBELL SCIENTIFIC, INC. will return such products by surface
carrier prepaid.  This warranty shall not apply to any CAMPBELL
SCIENTIFIC, INC. products which have been subjected to modification,
misuse, neglect, accidents of nature, or shipping damage.  This warranty is in
lieu of all other warranties, expressed or implied, including warranties of
merchantability or fitness for a particular purpose.  CAMPBELL SCIENTIFIC,
INC. is not liable for special, indirect, incidental, or consequential damages.

Products may not be returned without prior authorization.  The following
contact information is for US and International customers residing in countries
served by Campbell Scientific, Inc. directly.  Affiliate companies handle repairs
for customers within their territories.  Please visit www.campbellsci.com to
determine which Campbell Scientific company serves your country.  To obtain
a Returned Materials Authorization (RMA), contact CAMPBELL
SCIENTIFIC, INC., phone (435) 753-2342.  After an applications engineer
determines the nature of the problem, an RMA number will be issued.  Please
write this number clearly on the outside of the shipping container.
CAMPBELL SCIENTIFIC's shipping address is:

CAMPBELL SCIENTIFIC, INC.

RMA#_____
815 West 1800 North
Logan, Utah 84321-1784

CAMPBELL SCIENTIFIC, INC. does not accept collect calls.

Summary of Contents for Young 05103-LC

Page 1: ...INSTRUCTION MANUAL 05103 LC and 05305 LC R M Young Wind Monitor for MetData1 4 97 C o p y r i g h t c 1 9 8 4 1 9 9 7 C a m p b e l l S c i e n t i f i c I n c ...

Page 2: ... in lieu of all other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequential damages Products may not be returned without prior authorization The following contact information is for US and International customers residing in countries served by Campbell Scien...

Page 3: ...its use inside buildings 2 MOUNTING REQUIREMENTS The Wind Monitor mounts to a vertical piece of 1 IPS schedule 40 1 32 O D pipe See Figure 2 1 A band clamp at the base of the sensor is tightened to secure the sensor to the pipe Campbell Scientific supplies a 12 length of unthreaded pipe for mounting the wind monitor to Campbell Scientific s 019ALU Crossarm Sensor Mount 3 CONNECTION The wind monito...

Page 4: ...ero MetData1 Datalogger Program Instruction 01 P4 Excite Delay Measure 01 1 Rep 02 5 2500 mV slow 03 3 In Chan 04 2 Ex Chan 05 2 Delay Units 0 01 Sec 06 2500 mV Excitation 07 08 0 142 Mult 09 0 Offset Proper entry will vary dependent on input location assignment 5 MAINTENANCE AND REPAIRS R M Young suggests the anemometer bearings be inspected at least every 24 months Please refer to the R M Young ...

Page 5: ...This is a blank page ...

Page 6: ... campbellsci com br suporte campbellsci com br Campbell Scientific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Ltd CSL Campbell Park 80 Hathern Road Shepshed Loughborough LE12 9GX UNITED KINGDOM www campbellsci co uk sales campbellsci co uk Campbell Scientific Ltd France Miniparc du Verger Bat H 1 rue de Te...

Reviews: