FIGURE 7-27. CMB200 components
7.2.3.2 Assembly
1. Consult
(p. 35) and
(p. 36) to determine which brackets are needed
at either end of the brace to attach it to the crossarm and tower. The figure also indicates
what orientation is needed when the small bracket is used.
NOTE:
Each bracket has a long tab and short tab where the bolts are attached. The brace arm
must be attached to the end with the long tab.
2. Attach one end of the brace arm to the tower below the crossarm. Leave the bolts finger-
tight.
3. Lift the free end of the brace arm to the crossarm and attach it to the crossarm. Again, only
finger-tighten the bolts.
4. Adjust the position of the brace arm as needed.
5. Fully tighten the two bolts directly connected to the brace arm, and then tighten the
remaining two bolts to clamp the brace arm to the tower.