Appendix B. Example program
This following example measures one 109SS temperature probe once a second and stores the
average temperature every 60 minutes.
CRBasic Example 1: CR1000X program that measures the 109SS
'Program measures one 109SS temperature probe once a second and
'stores the average temperature every 60 minutes.
'Wiring Diagram
'==============
' Probe
' Wire Data logger
' Color Function Terminal
' ----- -------- ------
' Black Voltage-excitation input VX1/EX1
' Red Analog-voltage output SE1
' Purple Bridge-resistor ground Ground Symbol
' Clear Shield Ground Symbol
'Declare the variables for the temperature measurement
Public
T109SS_C
'Define a data table for 60 minute averages:
DataTable
(Hourly,True,-1)
DataInterval
(0,60,Min,0)
Average
(1,T109SS_C,IEEE4,0)
EndTable
BeginProg
Scan
(1,Sec,1,0)
'Measure the temperature
Therm109
(T109SS_C,1,1,Vx1,0,60,1.0,0.0)
'Call Data Table
CallTable
(Hourly)
NextScan
EndProg
109SS Temperature Probe