C-1
Appendix C. CS700H Operation Details
Factory settings have been set to adequately measure
precipitation during cold precipitation events. Changing
these settings is not recommended, and doing so may
change the data outcome or render the sensor inoperable.
shows the CS700H factory default settings for adequately
measuring precipitation during cold precipitation. Additionally, the default
setting for the SDI-12 address is zero.
TABLE C-1. CS700H Default Values
External Control Off (=> Auto)
(
a
X20!
Command) = 0
Snow Sensor Enabled
(
a
X22
! Command) = 1
Active On Temperature 4 °C
(
a
X23
! Command)
Active Off Temperature 5 °C
(
a
X24!
Command)
Low Off Temperature –20 °C
(
a
X25!
Command)
Funnel Set Point Temp 10°C
(
a
X26
! Command)
Snow Run-On Time 18 mins
(
a
X27
! Command)
Units °C
(
a
X28
! Command) = 0
SDI-12 Address 0
(
a
Ab!
Command to change address;
?!
Command to query address)
FIGURE C-1. Locations of the CS700H Heater Components