![Campbell SR50 Instruction Manual Download Page 15](http://html1.mh-extra.com/html/campbell/sr50/sr50_instruction-manual_3928820015.webp)
SR50 Sonic Ranging Sensor
9
TABLE 1. SR50 SDI-12 Command List
CR10X and
SDI-12
FUNCTION
DATA OUTPUT
CR23X P105
COMMANDS
Parameter 2
When using
Options non-Campbell
Loggers
0
aM
First Target (Meters)
D1
1
aM1
First Target (Meters)
D1,Q1
with
Quality
Number
2
aM2
Multiple Targets (Meters)
D1,D2,D3
3
aM3
Multiple Targets (Meters)
D1,D2,D3,Q1,Q2,Q3
with
Quality
Numbers
4
aM4
First Target (Feet)
D1
5
aM5
First Target (Feet)
D1,Q1
with Quality Number
6
aM6
Multiple Targets (Feet)
D1,D2,D3
7
aM7
Multiple Targets (Feet)
D1,D2,D3,Q1,Q2,Q3
with
Quality
Numbers
8
aM8
First Target (Meters)
D1
No Retries
N/A
aD0 Send
Data
DEPENDENT UPON
COMMAND
SENT
10
aV
Start Verification calculates
NUMERIC SIGNATURE
ROM
Signature
aI
Send Identification
012CAMPBELLSR50 1.1
NOTE: There are 2 spaces between SR50 and 1.1
0--
aC Concurrent
Measurement*
D1
n
--
aC
n
Concurrent Measurements*
Same as M – M8
Where a = address of SDI-12 device.
Where
n
= numbers 1 to 8.
* = see APPENDIX A for details about Concurrent Measurements.