Variable array
Description
Fan(5)
Fan control, greenhouse 1..5 SDM-CD16ACA
Port 11..15
CD16_Output(16)
Program SDM-CD16AC_greenhouse-control.dld: the actual values
used to control the SDM-CD16:
CD16_Output(I), I = 1 to 5 are for Heat,
I = 6 to 10 are for Cooling, I= 11 to 15 are for Fans
CD16_Output as Long
Program SDM-CD16AC_integer-set-control.dld: the actual value used
to control SDMCD the
CD16_Output bits set the SDM-CD16ACA ports.
bits 0 to 4 are for ‘Heat, 5 to 9 are for Cooling, 10 to 14 are for Fans
Program SDM-CD16AC_greenhouse-control.dld uses an array of values to set the
SDM-CD16ACA control outputs.
Program SDM-CD16AC_integer-set-control.dld has the same function as program
SDM-CD16AC_greenhouse-control.dld, but uses an integer instead of an array to set the
SDM-CD16ACA control outputs.
SDM-CD16ACA 16 Channel AC/DC Controller
12