background image

APPENDIX B.  TECHNICAL DETAILS OF SPECIAL MODES OF OPERATION

B-2

1

2

4

5

6

9

1

2

5

9

Datalogger

Pin No.

SC932C

9-Pin D
Pin No.

No connection to SC932C

No connection to SC932C

FIGURE B-1.  Connections for Using SC932C in ‘Printer’ Mode

(Other wires can be left connected or
disconnected.)

With this connection the SC932C can be
connected in parallel to another Campbell
Scientific modem-type device.  However, as
with the SC932, any data output to synchronous
devices (e.g., a Storage Module) will also be
transmitted out through the RS232 connection.

B.4  MAXIMUM RECALL INTERVAL

From the time that the datalogger leaves
communications mode (ME goes low), there is
a delay of approximately one second before
serial or ring line activity from the RS232 device
will re-awaken the datalogger.  This prevents
spurious messages from the RS232 device
(such as ‘loss of carrier’ messages from a
modem) waking up the datalogger.  The only
consequence of this delay is that specialized
software which polls dataloggers at frequent
intervals will not be able to wake the same
datalogger again during the delay period.

Campbell Scientific are aware of some modems
which will re-trigger the ring line, despite this
delay.  The only consequence of this is that the
datalogger will remain in communications mode
for an extra 30 seconds after the end of the call;
this will waste a small amount of power and
delay any output to a Storage Module.

Summary of Contents for SC932C 9-Pin

Page 1: ...INSTRUCTION MANUAL SC932C 9 Pin to RS 232 DCE Interface Revision 6 97 C o p y r i g h t c 1 9 9 7 C a m p b e l l S c i e n t i f i c I n c...

Page 2: ...all other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequen...

Page 3: ...DCE Interface A 1 A 2 Cable for Connection to a 9 Pin DCE Interface A 1 B Technical Details of Special Modes of Operation B 1 B 1 Power Modes B 1 B 2 Handshaking Lines B 1 B 3 Printer Only Output B 1...

Page 4: ...This is a blank page...

Page 5: ...C The SC932C can usually be connected to the RS232 device by plugging the SC932C directly into the serial connector on the RS232 device No further configuration is normally required A typical applicat...

Page 6: ...This is a blank page...

Page 7: ...SC932C to 25 pin DCE Interface NOTE The link between pins 4 and 4 marked with the may not be required see the section on low power operation in Appendix B A 2 CABLE FOR CONNECTION TO A 9 PIN DCE INTER...

Page 8: ...This is a blank page...

Page 9: ...s which do not need to source power from the SC932C This is done by not connecting pin 11 or the RTS line to the RS232 device This is because a small current will flow from the active RTS line into a...

Page 10: ...ves communications mode ME goes low there is a delay of approximately one second before serial or ring line activity from the RS232 device will re awaken the datalogger This prevents spurious messages...

Page 11: ...With 3 inputs connected DTR RTS and Tx from the SC932C of the minimum 3k input impedance and high communications activity the consumption may be up to 16mA RS232 OUTPUT LEVELS RTS 4 2 4 5V with 3k loa...

Page 12: ...active by SC932C 7 GND Signal Ground 11 in PWR If held 3 5V will force SC932C into high power mode 20 out DTR Held high if ME is high see Appendix B TABLE C 2 9 Pin Male Connector Pin out Pin No I O N...

Page 13: ...This is a blank page...

Page 14: ...campbellsci com br suporte campbellsci com br Campbell Scientific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientifi...

Reviews: