3.  Wiring

An internal or external battery is connected to the charger by means of the INT
(Internal) or EXT (External) connectors, as shown in Figure 1.  An “external
battery” cable comes with the charger that allows connecting another battery to
the charger to provide power if the main battery is removed.  The red lead
connects to the positive battery terminal and the black lead connects to the
negative terminal.

Reversal of polarity of external battery will damage the
PS12LA or PS512M.

It is possible to leave two batteries connected.  The battery connections are
diode isolated (Figure 3-2); however, if one of the batteries fail, it could draw
all the charging current and the other battery will be discharged.

A battery 

must

 be attached for the charger to function

correctly as a power supply.

The leads from the transformer or solar panel are connected to the CHG
terminals.  Polarity does not matter; either lead can be connected to either
terminal.

The wires that connect power to the datalogger and/or peripherals are
connected to the +12 and ground ( ) terminals.

INT

EXT

BATT

CHG

OFF

ON

CHG

CHG

+12

+12

FIGURE 1.  Wiring to Charger

WARNING

CAUTION

To Battery

From Transformer or Solar Panel 

{

To Datalogger or peripherals 

{

These look identical

when unplugged

Summary of Contents for PS12LA

Page 1: ...PS12LA PS512M CH12R CH512R POWER SUPPLIES AND CHARGING REGULATORS INSTRUCTION MANUAL 06 00 COPYRIGHT c 2000 CAMPBELL SCIENTIFIC INC ...

Page 2: ...This is a blank page ...

Page 3: ...arranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequential damages Products may not be returned without prior authorization To obtain a Returned Materials Authorization RMA contact CAMPBELL SCIENTIFIC INC phone 435 753 2342 After an applications engineer determines the nature of the problem an RMA number w...

Page 4: ...This is a blank page ...

Page 5: ...ally be connected to a datalogger These peripherals are typically modems linking different communications technologies e g telephone to radio 2 Specifications PS12LA PS512M CH12R CH512R Input Voltage CHG terminals 15 to 28 VDC or 18 VAC RMS Battery Connections Charging Output Voltage Temperature compensated float charge for 12 V Battery Temperature Compensation Range 40 to 60ºC Charging Current Li...

Page 6: ...is possible to leave two batteries connected The battery connections are diode isolated Figure 3 2 however if one of the batteries fail it could draw all the charging current and the other battery will be discharged A battery must be attached for the charger to function correctly as a power supply The leads from the transformer or solar panel are connected to the CHG terminals Polarity does not ma...

Page 7: ... PS512M and CH12R have two 9 pin CS I O ports on them with a null modem between them The ports are used to connect two 9 pin devices that would normally be connected to the CS I O port on a Campbell datalogger The charger supplies 12 volts and 5 volts to the appropriate pins on the connector for powering the connected devices This cannot be used as a null modem between two RS 232 devices CAUTION T...

Page 8: ...12LA PS512M CH12R CH512R Power Supplies and Charging Regulators 4 1 1 2 7 3 8 4 9 5 5 V GND HS Ring 12 V RX TX ME Ring RX TX ME 2 3 4 5 6 7 8 9 12 V 5 V 1 85 A Thermal Fuse FIGURE 3 Null Modem Connections ...

Reviews: