5.4 Wind speed measurements
Measurement range:
0.01 to 60 m/s
Resolution:
0.01 m/s
Starting threshold:
0.01 m/s
Accuracy:
±3% (up to 40 m/s), ±5% (up to 60 m/s)
5.5 Wind direction measurements
Measurement range:
0° to 359°
Resolution:
1°
Accuracy:
±3° (up to 60 m/s)
5.6 Precipitation input
Measurement input type: Triggering
Range:
0 to 1000 mm/hr
Resolution:
from 0.01 mm
Input to MetSENS550:
Contact closure via an M8 male, 4-pin connector.
User-supplied 20 m cable or mating female connector required.
5.7 Precipitation measurements
Measurement input type: Optical
Range:
0 to >300 mm/hr
Resolution:
0.08 mm
Repeatability:
3%
5.8 Compass
Measurement range:
0 to 359°
Resolution:
1°
Units of measure:
Degrees
Accuracy:
±3°