
Met One 034B Wind Set
9
7.2.2 Mount to Top of Tripod
The 034B can be attached to the top of a CM106B, CM110, CM115, or
CM120 tripod via the CM216 Sensor Mounting Kit (FIGURE
). The
CM216 extends 10 cm (4 in) above the mast of the tripod.
FIGURE 7-3. CM216 mount
7.3 Wiring
Connections to Campbell Scientific CRBasic dataloggers are given in TABLE
TABLE 7-1. Wire Colo
u
r, Wire Function, and Datalogger Connection
Wire Colo
u
r
Wire Function
Datalogger Connection
Terminal
Red
WS Signal
U
configured for pulse input
1
,
P
(pulse input), or
P_SW
(pulse, switch closure input)
Black
WS Signal Reference
⏚
Green
WD Signal
U
configured for single-ended
analog input
1
,
SE
(single-
ended, analog input)
Blue
WD Voltage Excitation
U
configured for voltage
excitation
1
,
EX
,
or
VX
(voltage
excitation)
White
WD Signal Reference
AG
or
⏚
(analog ground)
Clear
Shield
AG
or
⏚
(analog ground)
1
U
channels are automatically configured by the measurement instruction.