Campbell Met One 034B Instruction Manual Download Page 25

A-1

Appendix A.  Importing Short Cut Code 

Into CRBasic Editor 

This tutorial shows: 

How to import a 

Short Cut

 program into a program editor for

additional refinement

How to import a wiring diagram from 

Short Cut

 into the comments of

a custom program

Short Cut

 creates files, which can be imported into 

CRBasic Editor

. Assuming 

defaults were used when 

Short Cut

 was installed, these files reside in the 

C:\campbellsci\SCWin folder: 

.DEF (wiring and memory usage information)

.CR2 (CR200(X)-series datalogger code)

.CR300 (CR300-series datalogger code)

.CR6 (CR6-series datalogger code)

.CR8 (CR800-series datalogger code)

.CR1 (CR1000 datalogger code)

.CR3 (CR3000 datalogger code)

.CR5 (CR5000 datalogger code)

.CR9 (CR9000(X) datalogger code)

Use the following procedure to import 

Short Cut

 code and wiring diagram into 

CRBasic Editor

1. Create the 

Short Cut

 program following the procedure in Section 

4

,

QuickStart

 

(p. 2)

. Finish the program and exit 

Short Cut

. Make note of the

file name used when saving the 

Short Cut 

program.

2. Open 

CRBasic Editor

.

3. Click 

File

 | 

Open

. Assuming the default paths were used when 

Short Cut

was installed, navigate to C:\CampbellSci\SCWin folder. The file of

interest has the .CR6, .CR1, .CR8, or .CR3 extension. Select the file and

click 

Open

.

4. Immediately save the file in a folder different from

C:\Campbellsci\SCWin, or save the file with a different file name.

Once the file is edited with 

CRBasic Editor

Short Cut

  can no 

longer be used to edit the datalogger program.  Change the name 

of the program file or move it, or 

Short Cut

 may overwrite it next 

time it is used. 

5. The program can now be edited, saved, and sent to the datalogger.
6. Import wiring information to the program by opening the associated .DEF

file. Copy and paste the section beginning with heading “-Wiring for

CRXXX–” into the CRBasic program, usually at the head of the file. After

pasting, edit the information such that an apostrophe (

'

) begins each line.

This character instructs the datalogger compiler to ignore the line when

compiling.

NOTE 

Summary of Contents for Met One 034B

Page 1: ...INSTRUCTION MANUAL Met One 034B Wind Set Revision 9 16 C o p y r i g h t 1 9 8 0 2 0 1 6 C a m p b e l l S c i e n t i f i c I n c...

Page 2: ......

Page 3: ...under guarantee or not Please state the faults as clearly as possible and if the product is out of the guarantee period it should be accompanied by a purchase order Quotations for repairs can be give...

Page 4: ......

Page 5: ...digital cell phones and aerials may also not be applicable according to your locality Some brackets shields and enclosure options including wiring are not sold as standard items in the European marke...

Page 6: ......

Page 7: ...ore beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit...

Page 8: ......

Page 9: ...tion 5 6 3 General Specifications 6 7 Installation 6 7 1 Siting 6 7 2 Mounting Options 6 7 2 1 Mount to a Crossarm 6 7 2 2 Mount to Top of Tripod 9 7 3 Wiring 9 7 4 Programming 10 7 4 1 Wind Speed 10...

Page 10: ...orth to East of Magnetic North C 2 C 2 Declination Angles True North to West of Magnetic North C 3 C 3 Magnetic Declination at 2012 5 degrees relative to true north positive is east C 3 D 1 034B poten...

Page 11: ...ical wires Check for overhead wires before mounting the 034B or before raising a tower The set screw holes must be covered with labels to prevent corrosion and assure the warranty The black outer jack...

Page 12: ...e 1 Sensor cable of user specified length 4 QuickStart Short Cut is an easy way to program your datalogger to measure the 034B and assign datalogger wiring terminals Short Cut is available as a downlo...

Page 13: ...the Available Sensors and Devices list select the Sensors Meteorological Wind Speed Direction folder Select 034A 034B Wind Speed Direction Sensor Click to move the selection to the Selected device wi...

Page 14: ...diagram in step 4 check the output of the sensor in the datalogger support software data display to make sure it is making reasonable measurements 5 Overview The 034B Wind Set is used to measure hori...

Page 15: ...om cws900 for more information 6 Specifications Features Designed for continuous long term unattended operation in adverse conditions Constructed of light weight aluminum Compatible with Campbell Scie...

Page 16: ...ing the height of the sensors above the roof should be at least 1 5 times the height of the building See Section 9 References p 13 for a list of references that discuss siting wind speed and direction...

Page 17: ...URE 7 1 8 Insert the 034B into the aluminum bushing provided with the sensor see FIGURE 7 1 9 Align the hole in the bushing with that in the 034B base and replace the screw see FIGURE 7 1 10 Insert th...

Page 18: ...et One 034B Wind Set 8 FIGURE 7 1 034B mounted on a crossarm using a 17953 Nu Rail Crossover Fitting FIGURE 7 2 CM200 Series Crossarm with CM220 Right Angle Mounting Bracket CM220 CM200 Series Crossar...

Page 19: ...e Colour Wire Function and Datalogger Connection Wire Colour Wire Function Datalogger Connection Terminal Red WS Signal U configured for pulse input1 P pulse input or P_SW pulse switch closure input B...

Page 20: ...ely with Short Cut If your data acquisition needs are more complex the files that Short Cut creates are a great source for programming code to start a new program or add to an existing custom program...

Page 21: ...ple Program p B 1 for example Excitation voltages range codes and multipliers for our dataloggers are listed in TABLE 7 3 The multiplier value converts the sensor s millivolt output to degrees Appendi...

Page 22: ...beginning of this document for the procedure of returning the sensor to Campbell Scientific for bearing replacement 2 Years Replace the wind vane potentiometer and bearings Refer to the Assistance pa...

Page 23: ...losure Hertz and multiplier and offset parameters for the pulse count instruction are correct for the datalogger type 9 References The following references give detailed information on siting wind spe...

Page 24: ...Met One 034B Wind Set 14...

Page 25: ...the program and exit Short Cut Make note of the file name used when saving the Short Cut program 2 Open CRBasic Editor 3 Click File Open Assuming the default paths were used when Short Cut was instal...

Page 26: ......

Page 27: ...bles and Units Public Batt_Volt Public WS_ms Public WindDir Units Batt_Volt Volts Units WS_ms meters second Units WindDir degrees Define Data Tables DataTable Table1 True 1 DataInterval 0 60 Min 10 Wi...

Page 28: ......

Page 29: ...sily corrected by adding or subtracting the difference between the two readings as explained below Maps are always drawn in relation to the true north pole and ordnance survey maps will normally show...

Page 30: ...asily done with two people one person to aim and adjust the sensor and a second person to observe the wind direction readings from the datalogger Ideally use RS232 Direct Link to laptop computer to vi...

Page 31: ...lower orientation fitting band clamp on the Wind Sentry arm so that it can be rotated by hand Do not loosen the upper clamp 6 While holding the vane in the correct true north position at all times ca...

Page 32: ......

Page 33: ...ll Scientific has a 9 53 k fixed resistor and a variable resistor on the excitation line The variable resistor is adjusted by the manufacturer so its resistance plus the 9 53 k resistor equals the res...

Page 34: ...ua Apinag s nbr 2018 Perdizes CEP 01258 00 S o Paulo SP BRASIL www campbellsci com br vendas campbellsci com br Campbell Scientific Canada Corp 14532 131 Avenue NW Edmonton AB T5L 4X4 CANADA www campb...

Reviews: