Appendix B. Example Programs
DataTable(Table2,True,-1)
DataInterval(0,1440,Min,10)
Minimum(1,BattV,FP2,False,False)
EndTable
'Main Program
BeginProg
'Main Scan
Scan(5,Sec,1,0)
'Default Datalogger Battery Voltage measurement 'BattV'
Battery(BattV)
'Default Wiring Panel Temperature measurement 'PTemp_C'
PanelTemp(PTemp_C,60)
'LWS Dielectric Leaf Wetness Sensor measurement 'LWmV'
BrHalf(LWmV,1,mV5000,U2,U1,1,2500,False,10000,60,2500,0)
'Determine Minutes Dry 'LWMDry', Minutes Wet or Contaminated
'LWMCon', and Minutes Wet 'LWMWet' for this Scan
LWMDry=0
LWMCon=0
LWMWet=0
If LWmV<274 Then
LWMDry=0.08333333
Else
If LWmV>=284 Then
LWMWet=0.08333333
Else
LWMCon=0.08333333
EndIf
EndIf
'Call Data Tables and Store Data
CallTable Table1
CallTable Table2
NextScan
EndProg
B-3