EasyAG
®
Soil Water Content Profile Probes
4
6. Specifications
Feature
EasyAG
SDI-12
Maximum cable length to
logger or third party device
60 m (200 ft)*
Maximum sensors per
standard probe
4
Sensor Measuring Principle
High frequency capacitance
Output Options
SDI-12
Protocol options
SDI-12
Interface Measuring Principle 16 Bit pulse count
Output Resolution
16 Bit
Output Method
Serial data
Current Consumption
250
μ
A @ Sleep
66 mA @ Standby
100 mA @ Sampling
Reading range
Water Content/Salinity
0 to ~65%/0 to 17 dSm
-1
Temperature effects
r
3% 5°C to 35°C
Operating temperature range -20°C to +75°C
Time to read one sensor
1.1 seconds
Sphere of influence
99% of the reading is taken within a 10 cm
radius from the outside of the access tube
Sensor diameter
26.5 mm
Access tube diameter
32 mm
Probe length
50 cm (20 inches)
* Based on SENSDI12CBL-L cable.
Summary of Contents for EasyAG SDI-12
Page 2: ......
Page 3: ......
Page 26: ...Appendix A Normalization and Function Test A 6 ...
Page 40: ...Appendix B Tube Installation B 14 ...
Page 42: ...Appendix C Site Selection C 2 ...