CPI star topology
If several CSAT3Bs using CPI communications are being connected in parallel or with a star
topology, connect a CSAT3BCBL2 cable to each Power/SDM port of each CSAT3B, and connect
the other wires to the 12 V and G terminals of a data logger or to a separate 12 to 32 VDC
nominal power supply. (For convenience, it is possible to use a wiring bus, such as the HUB-
SDM8, to bring several power wires together and then extend a single cable, such as the
CABLEPCBL-L, from the bus to the power supply.)
Connect a CSAT3BCBL3 to each CPI/RS-485 port of each CSAT3B, and connect the opposite end,
which should have RJ45 connectors, to a HUB-CPI. Then, use a CAT5e or CAT6 Ethernet cable to
connect the HUB-CPI to the CPI port of a data logger. The CSAT3HCBL1-L cables from each
CSAT3H heater controller box can either all go into the same ports, or all wires can re-route to a
terminal connector with one set of wires routed to the data logger for a cleaner configuration.
Refer to
(p. 57) for these connections.
NOTE:
The sockets or ports on the HUB-CPI are all the same. Any socket may be used to connect to
the data logger or to other CSAT3Bs.