Appendix B. Example Programs
B-2
Public CS650(6)
Public CS650_2(6)
DataTable (DatoutCS650,1,-1)
DataInterval (0,60,Min,2)
Average (3,CS650(1),FP2,False)
Sample(3,CS650(4),IEEE4)
Average (3,CS650_2(1),FP2,False)
Sample(3,CS650_2(4),IEEE4)
EndTable
BeginProg
Scan (15,Min,0,0)
SDI12Recorder (CS650(1),1,0,"M3!",1.0,0)
SDI12Recorder (CS650_2(1),1,1,"M3!",1.0,0)
CallTable DatoutCS650 'Call Data Table
NextScan
EndProg
B.1.3 CR1000 with 12 CS650 Probes on Multiplexer
This CRBasic example program measures 12 CS650 probes on a AM16/32B
multiplexer every 15 minutes, storing hourly averages of volumetric water
content, electrical conductivity, soil temperature, permittivity, period average, and
voltage ratio. All probes are addressed with SDI-12 address of 0. In this example,
the probes are powered through the switched 12V channel and require 3 seconds
warm-up time per probe. Total time to measure all 12 probes is more than 36
seconds. Alternately, all of the red wires for the probes could be connected to a
bus separate from the multiplexer with the bus connected to 12V for continuous
power. This would decrease measurement time. Wiring for the example is shown
in Table
. Assignment of aliases and units is not shown in this example.
Table B-3. CR1000 Wiring For Multiplexer Example Program
CR1000
AM16/32B (2x32 mode)
CS650
12V
12V
G
GND
C2
RES
C3
CLK
SW12
COM ODD H
C1
COM ODD L
G
COM Ground
High Channels 1H – 12H
Red
Low Channels 1L – 12L
Green
Ground Channels to Left of
Low Channels
Black, Orange, Clear