![Campbell CS140 Product Manual Download Page 29](http://html1.mh-extra.com/html/campbell/cs140/cs140_product-manual_3811056029.webp)
Table 6-5: POLL transmitted data
Example
Description
0x02
1
STX
POLL
POLL command
:
Delimiting character
0
Address based on sensor ID
:
Delimiting character
0
Reserved for future use; zero default
:
Delimiting character
3A3B
Checksum
:
Delimiting character
0x03
1
ETX
0x0D
1
Carriage return
1
These values are shown in hexadecimal format not ASCII.
6.5 Menu system
When connected to the CS140, the user can enter the menu system by typing open id in their
terminal program then pressing the return key on their keyboard. The ID corresponds to the
sensor ID number. The sensor ID number can be in the range of 0 to 9. The factory default is 0.
NOTE:
The
open 0
command is not normally echoed. The terminal menu only gives access to more
common settings.
CS140 Background Luminance Sensor
23