COM310 Voice Communications Modem
Unlike the CR10X, CR510 and CR23X where voice code is appended to a
finished measurement program using LoggerTalk software, the CR1000 voice
code is created along with the measurement program using the CRBasic editor.
It is recommended you finish and debug the voice portion of your program
first, and then add the measurement code.
The example CR1000 voice callback/callin program that follows supports the
following functions:
•
Voice callin
•
Voice callback
•
Auto-disconnect
•
Auto redial
•
Alarm reset
The following steps show how to build a station to demo the example voice
callback/callin program. The voice station can further serve to test/debug your
custom voice program and merge it with your application program.
Step 1 – LoggerNet Setup
1)
In LoggerNet Setup create the following device map
2)
Configure ComPort and PhoneBase for your PC’s phone modem.
3)
Configure PhoneRemote to include the COM310’s analog phone number
followed by six commas and a 9.
4)
Click on CR1000phone (renamed) and verify that the PakBus Address is 1.
Step 2 – Hardware Setup
1)
Start with a CR1000 having factory settings. If unsure of settings, close
LoggerNet, connect SC12 cable from PC ComPort to CR1000 RS-232
port, run Device Configuration Utility, set Serial Port to match the PC
ComPort, Connect and click on the Factory Defaults button, Apply
settings and Disconnect.
2)
Connect CR1000 to PS100 (turned off).
3)
Connect SC12 cable from COM310 to CR1000 CS I/O port.
4)
Connect analog phone line to COM310.
5)
Turn on PS100.
6)
Connect prepared TC to CR1000’s DIFF 7 analog input.
7)
Connect LED with 1000 Ohm resistor connected to anode lead from C1 to
G (resister to C1).