![Campbell CM106B Product Manual Download Page 21](http://html1.mh-extra.com/html/campbell/cm106b/cm106b_product-manual_3729659021.webp)
CM106B Tripod
15
6.1.6 Crossarm Attachment
For a video demonstrating how to attach a crossarm to a tripod, see
www.campbellsci.com/videos/tripod5
Attach the CM202 (0.6 m, 2 ft), CM204 (1.2 m, 4 ft), or CM206 (1.8 m, 6 ft)
crossarm to the tripod mast as shown in FIGURE
. For wind sensors, the
crossarm should be approximately 2.6 m (103 in) above the ground for a 3 m
mounting height, or 1.6 m (64 in) for a 2 m mounting height. Typically, the
crossarm is oriented East/West for wind sensors, North/South for
pyranometers.
FIGURE 6-10. CM204 Crossarm
6.1.7 Enclosure Attachment
The ENC10/12, ENC12/14, ENC14/16, and ENC16/18 enclosures can be
ordered with mounting brackets for the CM106B tripod. All enclosure models
can be mounted to the tripod mast (above the legs) with the –MM Mast Mount
bracket option. The –LM Leg Mount bracket option allows all enclosure
models to be mounted to the tripod base. Two enclosures with the –LM
brackets can be mounted in a “back to back” configuration.
6.1.7.1 Enclosure Mounting to Tripod Mast
For a video showing how to mount an enclosure to the tripod mast, see
www.campbellsci.com/videos/tripod4
An enclosure ordered with the –MM bracket has a three-piece top and bottom
brackets with a U-bolt for each bracket.
Attach an enclosure with the –MM mounting bracket to the tripod mast as
follows:
Remove the U-bolts, washers, and nuts from the brackets.
Position the enclosure against the tripod mast (North side recommended).
CM200 Series
Crossarm
Tripod Mast