![background image](http://html1.mh-extra.com/html/campbell/ce1000/ce1000_operating-instructions-and-parts-manual_3720070011.webp)
MAINTENANCE /
REP
AIR
TROUBLESHOOTING
OPERA
TION
ASSEMBL
Y /
INST
ALLA
TION
SAFETY /
SPECIFICA
TIONS
GETTING ST
AR
TED
9
3. Install air filter. See Figure 5.
Lubrication
Recommended Oil (2 Options)
Single viscosity SAE 30 ISO100 nondetergent compressor
oil. Part number ST125303AV (0.5 qt) or ST126701AV (4
qt).
10W30 synthetic oil such as Mobil 1
®
or CE0032 (1 qt).
Oil Capacity
Approximately 15.2 oz.
Remove oil fill plug on pump. Check oil level; some
models are shipped with oil in the pump. Add oil
if needed. Fill the pump with oil to the center of
the sight gauge using oil fill opening (see Figure 7).
Place oil fill plug back on pump.
Do NOT fill the pump
through the breather cap opening as this may cause oil to
leak and spray out during operation.
Do not use regular automotive oil. Additives in
regular motor oil can cause valve deposits and
reduce pump life.
For maximum pump life, drain and replace oil after
the first 50 hours of run time and then follow the
regular maintenance schedule outlined later in the
manual.
This pump has an oil sight glass as shown in Figure 6.
Oil level can be monitored and maintained as shown
in Figure 7.
NOTE:
Some residual oil may still be in the pump
from factory testing leaving a thin coat on the sight
gauge; however, there is not enough oil to operate
the unit.
Figure 5
Air Filter
Figure 7
Full
Low
Sight Glass
Figure 6
Oil Fill Area
Oil Drain Plug
Sight Glass
This unit contains no oil. Before operating
compressor, fill to the center of the sight gauge
(see Figure 7).
Using any other type of oil may shorten pump life
and damage valves.
Summary of Contents for CE1000
Page 67: ...NOTES NOTAS...