Safety

 

DANGER 

 MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON 

OR AROUND 

TRIPODS, TOWERS, AND ANY ATTACHMENTS TO TRIPODS AND TOWERS SUCH AS SENSORS, 

CROSSARMS, ENCLOSURES, ANTENNAS, ETC

.  FAILURE TO PROPERLY AND COMPLETELY ASSEMBLE, 

INSTALL, OPERATE, USE, AND MAINTAIN TRIPODS, TOWERS, AND ATTACHMENTS, AND FAILURE TO HEED 
WARNINGS, INCREASES THE RISK OF DEATH, ACCIDENT, SERIOUS INJURY, PROPERTY DAMAGE, AND 
PRODUCT FAILURE.  TAKE ALL REASONABLE PRECAUTIONS TO AVOID THESE HAZARDS.  CHECK WITH YOUR 
ORGANIZATION'S SAFETY COORDINATOR (OR POLICY) FOR PROCEDURES AND REQUIRED PROTECTIVE 
EQUIPMENT PRIOR TO PERFORMING ANY WORK. 

Use tripods, towers, and attachments to tripods and towers only for purposes for which they are designed.  Do not 
exceed design limits.  Be familiar and comply with all instructions provided in product manuals.  Manuals are 
available at www.campbellsci.eu or by telep44(0) 1509 828 888 (UK).  You are responsible for conformance 
with governing codes and regulations, including safety regulations, and the integrity and location of structures or land 
to which towers, tripods, and any attachments are attached.  Installation sites should be evaluated and approved by a 
qualified engineer.  If questions or concerns arise regarding installation, use, or maintenance of tripods, towers, 
attachments, or electrical connections, consult with a licensed and qualified engineer or electrician. 

General 

Prior to performing site or installation work, obtain required approvals and permits. Comply with all

governing structure-height regulations, such as those of the FAA in the USA.

Use only qualified personnel for installation, use, and maintenance of tripods and towers, and any

attachments to tripods and towers.  The use of licensed and qualified contractors is highly recommended.

Read all applicable instructions carefully and understand procedures thoroughly before beginning work.

Wear a hardhat and eye protection, and take other appropriate safety precautions while working on or

around tripods and towers.

Do not climb tripods or towers at any time, and prohibit climbing by other persons. Take reasonable

precautions to secure tripod and tower sites from trespassers.

Use only manufacturer recommended parts, materials, and tools.

Utility and Electrical 

You can be killed or sustain serious bodily injury if the tripod, tower, or attachments you are installing,

constructing, using, or maintaining, or a tool, stake, or anchor, come in contact with overhead or

underground utility lines.

Maintain a distance of at least one-and-one-half times structure height, or 20 feet, or the distance

required by applicable law, whichever is greater, between overhead utility lines and the structure (tripod,

tower, attachments, or tools).

Prior to performing site or installation work, inform all utility companies and have all underground utilities

marked.

Comply with all electrical codes.  Electrical equipment and related grounding devices should be installed

by a licensed and qualified electrician.

Elevated Work and Weather 

Exercise extreme caution when performing elevated work.

Use appropriate equipment and safety practices.

During installation and maintenance, keep tower and tripod sites clear of un-trained or non-essential

personnel.  Take precautions to prevent elevated tools and objects from dropping.

Do not perform any work in inclement weather, including wind, rain, snow, lightning, etc.

Maintenance 

Periodically (at least yearly) check for wear and damage, including corrosion, stress cracks, frayed cables,

loose cable clamps, cable tightness, etc. and take necessary corrective actions.

Periodically (at least yearly) check electrical ground connections.

WHILE EVERY ATTEMPT IS MADE TO EMBODY THE HIGHEST DEGREE OF SAFETY IN ALL CAMPBELL 
SCIENTIFIC PRODUCTS, THE CUSTOMER ASSUMES ALL RISK FROM ANY INJURY RESULTING FROM IMPROPER 
INSTALLATION, USE, OR MAINTENANCE OF TRIPODS, TOWERS, OR ATTACHMENTS TO TRIPODS AND TOWERS 
SUCH AS SENSORS, CROSSARMS, ENCLOSURES, ANTENNAS, ETC. 

Summary of Contents for A300

Page 1: ...A300 Power and Signal Converter Revision 09 2022 Copyright 2015 2022 Campbell Scientific CSL I D 1111 ...

Page 2: ...s under guarantee or not Please state the faults as clearly as possible and if the product is out of the guarantee period it should be accompanied by a purchase order Quotations for repairs can be given on request It is the policy of Campbell Scientific to protect the health of its employees and provide a safe working environment in support of this policy a Declaration of Hazardous Material and De...

Page 3: ... cell phones and aerials may also not be applicable according to your locality Some brackets shields and enclosure options including wiring are not sold as standard items in the European market in some cases alternatives are offered Details of the alternatives will be covered in separate manuals Part numbers prefixed with a symbol are special order parts for use with non EU variants or for special...

Page 4: ...e beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit climbing by other persons Take reasonable precautions to secure tripod and tower sites from trespassers Use only manufacturer recommended parts materials and tools Utility and Electrical You can be kil...

Page 5: ...nspection 1 4 Specifications 1 5 Installation 2 5 1 A300 Cable and Terminal Description 2 5 2 Using With GPS16X HVS 2 5 3 Using With 3 3 V Serial Sensor 3 5 4 Mounting 3 Tables 5 1 GPS16X HVS Wiring to A300 Terminals and Datalogger Terminals 2 5 2 A300 Cable Wiring to Datalogger Terminals 2 5 3 Sensor Wiring to A300 Terminals and Datalogger Terminals 3 5 4 A300 Cable Wiring to Datalogger Terminals...

Page 6: ...s 3 Initial Inspection Upon receipt of the A300 inspect the packaging and contents for damage File damage claims with the shipping company 4 Specifications Dimensions Cable Terminals Mounting Packaging Temperature Supply Voltage Supply Current Power Output 5 V Signal Input 5 V Signal Output 3 V Signal Input 3 V Signal Output Maximum Voltage Translation Rate 78 x 46 x 9 3 mm 3 08 x 1 8 x 0 36 in 30...

Page 7: ... have a PPS output of 0 to 3 V For those units an A300 is needed to connect the PPS output to a CR800 series CR1000 or CR3000 datalogger Those dataloggers require the PPS line to have a voltage of 3 8 V or greater TABLE 5 1 GPS16X HVS Wiring to A300 Terminals and Datalogger Terminals GPS16X HVS Wire Colour GPS16X HVS Wire Function A300 Terminal Datalogger Red 12 V 12V Black Ground G Yellow Enable ...

Page 8: ... Wiring to A300 Terminals and Datalogger Terminals Sensor A300 Terminal 3 3 V Power In 3 3V PWR Ground G TxD Output 3 3V IN RxD Input 3 3V OUT TABLE 5 4 A300 Cable Wiring to Datalogger Terminals A300 Wire Colour A300 Wire Function Datalogger Red 12 V 12V Black Ground Ground Green 5 V Signal Input Tx Output White 5 V Signal Output Rx Input 5 4 Mounting The A300 provides several features to aide in ...

Page 9: ...info campbellsci fr www campbellsci fr Germany Location Phone Email Website Bremen Germany 49 0 421 460974 0 info campbellsci de www campbellsci de India Location Phone Email Website New Delhi DL India 91 11 46500481 482 info campbellsci in www campbellsci in South Africa Location Phone Email Website Stellenbosch South Africa 27 21 8809960 sales campbellsci co za www campbellsci co za Spain Locati...

Reviews: