Propeller description:
4-blade helicoids propeller molded of carbon fiber thermoplastic
Dimensions
Overall length:
43 cm (17 in)
Propeller diameter:
20 cm (8 in)
Housing diameter:
2.5 cm (1 in)
Mounting pipe description: 12-in. long, 3/4-in. IPS schedule 40 pipe (1.05 in. OD)
Weight:
0.5 kg (1.2 lb)
1
Threshold and distant constant values are for axial flows.
7. Installation
If you are programming your data logger with
Short Cut
, skip
(p. 6) and
Short Cut
does this work for you. See
(p. 2) for a
Short Cut
tutorial.
7.1 Wiring
Connections to Campbell Scientific data loggers are given in
Table 7-1: Wire color, wire function, and data logger connection
Wire color
Wire function
Data logger connection terminal
White
Signal
U configured for single-ended analog input
1
,
SE (single-ended, analog-voltage input)
Black
Signal reference
⏚
(analog ground)
Clear
Shield
⏚
(analog ground)
1
U terminals are automatically configured by the measurement instruction.
7.2 Programming
Short Cut
is the best source for up-to-date data logger programming code. If your data
acquisition requirements are simple and you are connecting the sensor to a pulse terminal, you
can probably create and maintain a data logger program exclusively by using
Short Cut
. If your
data acquisition needs are more complex, the files that
Short Cut
creates are a great source for
programming code to start a new program or add to an existing custom program.
27106T Vertical Propeller Anemometer
6