24
①
Method to adjust the lunar age indication error within ±0.24 (recommended)
First indication error
Movement of the 24-hour dial
Adjustment degree
Indication error after
adjustment
−0.5 to −0.24
Rotate 30 times to the right
+0.48
−0.02 to +0.24
−0.24 to +0.24
None
+0.24 to +0.5
Rotate 30 times to the left
−0.48
−0.24 to +0.02
②
Method to adjust the lunar age indication error within ±0.18
First indication error
Movement of the 24-hour dial
Adjustment degree
Indication error after
adjustment
−0.5 to −0.3
Rotate 30 times to the right
+0.48
−0.02 to +0.18
−0.3 to −0.26
Rotate 89 times to the right
+0.44
+0.14 to +0.18
−0.26 to −0.22
Rotate 118 times to the left
+0.08
−0.18 to −0.14
−0.22 to −0.18
Rotate 59 times to the left
+0.04
−0.18 to −0.14
−0.18 to +0.18
None
+0.18 to +0.22
Rotate 59 times to the right
−0.04
+0.14 to +0.18
+0.22 to +0.26 Rotate 118 times to the right
−0.08
+0.14 to +0.18
+0.26 to +0.3
Rotate 89 times to the left
−0.44
−0.18 to −0.14
+0.3 to +0.5
Rotate 30 times to the left
−0.48
−0.18 to +0.02
Setting the time and 24-hour/lunar age dials