See that the knob is turned clockwise to a 

full stop.

2.  Check that the 

control knob on the 

fire pit is turned off.

3.  Remove the 

protective cap from 

the LP tank valve 

and coupling nut,  

if present.

4.  Hold the regulator 

in one hand and 

insert the nipple 

into the valve outlet. 

Be sure the nipple 

is centered in the 

valve outlet. The 

coupler connects 

to the large outside 

threads on the valve outlet

5.  Hand tighten the coupler clockwise until it 

comes to a full stop. Firmly tighten by  

hand only.

The fire pit is to be used only with the 20 

pound, vertical standing vapor withdrawal type 

tank. This fire pit is designed to operate on 

propane gas only. The 20 lb LP cylinder used 

with this fire pit must conform to the following 

requirements:

• Type 1 Connections

• Diameter - 12" / 31.1cm

• Height - 18.25" / 46cm

•  9.07 kg / 20 lb LPG capacity or 21.6 kg / 

47.6 lb water capacity

•  Must be provided with a listed overfilling 

prevention device

The gas cylinder used must include a collar 

to protect the cylinder valve. The cylinder 

supply system must be arranged for vapor 

withdrawal.

Follow the instructions stated on gas cylinder 

tanks when filling or transporting tanks. 

Failure to do so could result in problems 

relating to overfilling, excessive venting 

release of gas and to regulator freezing. Never 

fill the cylinder more than 80 percent full.

 CAUTION

In the connection process, the HVR side 

of the connection will seal on the back 

check in the valve, resulting in a slight 

resistance. The connection requires about 

one-half to three quarters additional turn 

to complete connection. Any fuel supply 

cylinder used must be constructed and 

marked in accordance with specifications for 

propane cylinders of the U.S. Department of 

Transportation (DOT)CFR 49 or CAN/CSA 

B339.

Do not allow dirt or foreign material to get 

into or onto tank connection when it is not 

attached to the fuel supply system. Use the 

protective cap provided. Place dust cap on 

cylinder valve outlet whenever the cylinder is 

not in use. Only install the type of dust cap on 

the cylinder valve outlet that is provided with 

the cylinder valve. Other types of caps or plugs 

may result in leakage of propane. Cylinders 

must be filled before initial use. All handling, 

transport, filling and storage of LP gas 

cylinders must be in accordance with NFPA 

58 Storage and Handling of Liquid Petroleum 

Gasses, or CAN/CSA b149.2 Propane 

Installation Code.

 CAUTION

The gas pressure regulator provided with 

this appliance must be used. This regulator 

is set for an outlet pressure of 11" H20. 

Replacement pressure regulators and hose 

assemblies must be those specified by the 

fire pit manufacturer. See rating sticker on 

side of fire pit for regulator model number. 

The regulator/hose assembly should be 

handled carefully to prevent contamination 

by foreign objects and dirt. The assembly 

should be inspected before use and any dirt 

or contamination should be wiped off. The 

hose assembly must be replaced prior to the 

appliance being used if there is any evidence 

of excessive abrasion or wear, or if the 

hose is damaged. In order to insure proper 

operation, any replacement of the regulator 

assembly must be with parts authorized by 

manufacturer. Valve/pressure regulators 

are factory set to the correct operating 

pressures. No attempts should be made to 

adjust these settings.

(B) Nipple 

has to be 

centered 

into the LP 

tank valve

(C) Hold 

coupling nut 

and regulator 

as shown 

for proper 

connection to 

LP tank valve

Summary of Contents for PONDEROSA GF24D

Page 1: ...Outdoor decorative gas appliance Ansi Z21 97 2017 CSA 2 41 2017 WARNING INSTRUCTION BOOKLET MODEL GF24D PONDEROSA...

Page 2: ...e DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in an enclosed space such as a camper t...

Page 3: ...4 GF24 10 Lid button 1 5 GF24 3 Burner 1 6 GF24 4 Knob Bezel 1 7 FP29LG 26 Knob 1 8 GF24 11 Air damper 1 9 GF24 5 Heat Deflector 1 10 GF24 6 Flame distributor 1 11 GF18 3 Valve 1 12 GF24 7 Manifold 1...

Page 4: ...t near gasoline or other combustible liquids or where combustible vapors may be present Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid...

Page 5: ...ions exactly could result in a fire causing death or serious injury While the fire pit is not in use the gas must be turned off at the supply cylinder The fire pit should be shut off and all supply va...

Page 6: ...ked in accordance with specifications for propane cylinders of the U S Department of Transportation DOT CFR 49 or CAN CSA B339 Do not allow dirt or foreign material to get into or onto tank connection...

Page 7: ...tory authorized parts as specified by the manufacturer OPERATING INSTRUCTIONS Lighting Procedures 1 Check all connections for leaks using the soapy water test 2 Check for any blockage to the venturi t...

Page 8: ...sed by misuse abuse overheating and alteration No alterations are covered in this warranty Camp Chef is not responsible for any loss due to neglectful operation Furthermore this warranty does not cove...

Page 9: ...9 Outdoor decorative gas appliance Ansi Z21 97 2017 CSA 2 41 2017 LIVRET D AVERTISSEMENTS ET D INSTRUCTIONS MOD LE GF24D PONDEROSA...

Page 10: ...Cet appareil peut produire du monoxyde de carbone qui est inodore Une utilisation en espace ferm peut entra ner la mort Ne jamais utiliser cet appareil en espace ferm comme dans une caravane une tent...

Page 11: ...u couvercle 1 5 GF24 3 Br leur 1 6 GF24 4 Lunette de bouton 1 7 FP29LG 26 Bouton 1 8 GF24 11 Registre d air 1 9 GF24 5 D flecteur de chaleur 1 10 GF24 6 R partiteur de flamme 1 11 GF18 3 Soupape 1 12...

Page 12: ...ent feu de camp au gaz Le fait de ne pas positionner les pi ces conform ment ces sch mas ou de ne pas utiliser uniquement des pi ces sp cifiquement approuv es avec cet appareil peut entra ner des domm...

Page 13: ...ois Entreposer le feu de camp dans un endroit sec et prot g Le pr sent feu de camp n est pas con u pour tre un appareil de chauffage et ne peut jamais tre utilis cette fin NE PAS laisser fonctionner l...

Page 14: ...p le tuyau le d tendeur et la bouteille de gaz doivent tre plac s perpendiculairement par rapport la direction du vent Placer la bouteille de gaz une distance inf rieure 1 2 m 48 pi du feu de camp peu...

Page 15: ...givre sur le d tendeur Ne jamais remplir la bouteille plus de 80 de sa pleine capacit ATTENTION Au cours du processus de raccordement le raccordement du d tendeur adh rera herm tiquement la valve de s...

Page 16: ...uit avec des combustibles pour lesquels il n est pas pr vu annule la garantie du fabricant Le pr sent appareil ne peut tre raccord une conduite de gaz qui n est pas directement raccord e une bouteille...

Page 17: ...flamme du br leur doit alors s teindre Fermer le robinet de la bouteille de gaz GPL en tournant fond le bouton dans le sens des aiguilles d une montre Suivre les consignes de la pr sente notice pour l...

Page 18: ...ouragans les tornades les inondations la foudre les incendies ou le non respect des consignes d utilisation LES GARANTIES IMPLICITES VENTUELLES PR VUES PAR LA LOI NE SERONT EN AUCUN CAS TENDUES AU DEL...

Page 19: ...19 FOLLETO DE ADVERTENCIAS E INSTRUCCIONES MODELO GF24D Outdoor decorative gas appliance Ansi Z21 97 2017 CSA 2 41 2017 PONDEROSA...

Page 20: ...RO MON XIDO DE CARBONO Este aparato puede producir mon xido de carbono que no tiene olor Usarlo en un espacio cerrado le puede matar a usted Nunca use este aparato en un espacio cerrado tal como una a...

Page 21: ...4 GF24 10 Lid button 1 5 GF24 3 Burner 1 6 GF24 4 Knob Bezel 1 7 FP29LG 26 Knob 1 8 GF24 11 Air damper 1 9 GF24 5 Heat Deflector 1 10 GF24 6 Flame distributor 1 11 GF18 3 Valve 1 12 GF24 7 Manifold 1...

Page 22: ...en producir da os materiales o lesiones personales NICAMENTE PARA USO EN EXTERIORES No ponga en funcionamiento el fog n en interiores en un garaje ni en ninguna otra zona cerrada o bajo una construcci...

Page 23: ...s maneja el fog n Deje que fog n y sus componentes se enfr en completamente antes de realizar cualquier tarea de limpieza o mantenimiento NO mueva el fog n cuando lo est usando Deje que el fog n se en...

Page 24: ...interior del anillo de soporte del dep sito en cuenta No utilice pozo de fuego si el tanque no est dentro del anillo de soporte o con el dep sito en la posici n incorrecta ADVERTENCIA PELIGRO DE TROP...

Page 25: ...enamiento de cilindros de gas LP deben estar en conformidad con la norma NFPA 58 Almacenamiento y Manejo de Gases Licuados del Petr leo o CAN CSA B149 2 C digo de instalaci n de propano PRECAUCI N Se...

Page 26: ...gire lentamente a la posici n de bajo El encendedor emitir chispas y el gas se encender Espere 15 segundos tras la ignici n antes de soltar el mando Si la llama no se enciende inmediatamente apague la...

Page 27: ...UN PRODUCTO DEFECTUOSO EN NING N CASO SEREMOS RESPONSABLES POR DA OS ESPECIALES IMPREVISTOS O DERIVADOS QUE SURJAN DE LA COMPRA O DEL USO DE ESTE PRODUCTO YA SEA EN VIRTUD DE UN CONTRATO ACUERDO EXTR...

Page 28: ...28 www CampChef com 1 800 650 2433 Camp Chef is a registered trademark of Logan Outdoor Products 2021 301 N Camp Chef Way Hyde Park UT 84318 USA Made in China 0222_GF24D_Instructions...

Reviews: