background image

Camozzi spa

Società Unipersonale

Via Eritrea, 20/I

25126 Brescia - Italy

Tel. +39 030 37921 

Fax +39 030 2400430

[email protected]

www.camozzi.com

Technical assistance

Products inquiries and 

requests for support

Tel. +39 030 3792790

[email protected]

Product Certification

Information concerning   

product certifications, EC standards, 

conformity declarations and instruction

[email protected]

Series TC 

Pressure regulator cartridge

Use and maintenance instructions

 

• Some risks can be related to the product only after its installation on the 

  machinery/equipment. The end user is responsible for the identification of the 

  potential safety issue and the reduction of the risks.

• The products described in this manual can be used in circuits which comply with 

  EN ISO 13849-1 norm

• For information regarding the product reliability please contact Camozzi S.p.A.

• Before using the product, read carefully the information contained in this 

  document.

• The instructions contained in this manual must be followed together with the 

  instructions and other information available in:

- Website http://www.camozzi.com 

- Camozzi general catalogue 

- Camozzi technical support.

• Mounting and operation must be carried out only by qualified and authorized 

  employees, in accordance with these instructions.

• The machinery/ equipment designer is responsible for choosing the proper 

  pneumatic component in accordance with its application.

• In case of applications which are not described in this manual or in case of 

  risks for things, persons or animals, please contact Camozzi S.p.A. before using  

  the product.  

• Do not make any alterations of the product if not authorized, otherwise the user is  

  responsible for any subsequent damage to things, people or animals.

• All safety rules related to the product must be respected.

• Do not work with the machinery/equipment without having checked that the 

  working conditions are safe.

• Before the product’s installation or maintenance take care that any lock-out 

  controls are safely activated. The power supply should then be removed 

  (if necessary) along with the pressure supply system before exhausting all 

  residual compressed air in the system. Drain any residual energy stored in 

  springs, capacitors, reservoirs or vessels. Be aware of any machinery movement 

  due to gravity when the air is removed from the system.

• The working conditions must be kept between the limitations established 

  by the technical specifications that can be found under the section “General 

  Characteristics” of this document and/or in Camozzi general catalogue.

  Use the product complying the technical specification contained in the section 

• Unless special applications are allowed, do not use the product in environment  

  where the product might be in direct contact with corrosive gases, chemicals,  

  salted water, steam or water.

• Avoid, where possible, the installation of devices:

  - Where there is direct exposure to sunlight (provide shielding where necessary);

  - In proximity of any heat source or in areas subjected to sudden changes in  

    temperature.

• Before performing any maintenance on the regulator, is to disconnect the 

  compressed air source allow the release of any residual pressure inside the regulator.

• For this type of product, maintenance or revisions are possible only at a service  

  center Camozzi S.p.A.

• At the end of the product life cycle, the recyclable-material collection is advisable.

• Comply with the disposal of waste material regulations in force in your country.

The regulator Series TC 

regulates and maintains the air 

pressure to the desired value, 

which can obviously not be 

higher than the line pressure. 

In order to regulate you need 

to turn the regulation screw (

A

), 

rotating it clockwise or 

anti-clockwise, in any case 

the right regulation of the 

pressure has to be set upwards 

and then block the rotation.

The air flow has to follow the 

direction from “

1

” to “

2

”.

Use the nut (

B

) to block the 

regulation and avoid accidental 

setting changes.

When installing the regulator 

cartridge on its sub-base 

or in a seat made for a specific 

customer application, insert 

the O-ring (

C

) and then fix 

the regulator cartridge using 

screws (

D

), both supplied.

• During the product’s unpacking be careful not to damage it. 

• Check that no damages due to transportation or storage are present.

• Do not through away the packaging materials, take care of the disposal and  

  reconversion of the waste material in compliance with the local regulations.

• Avoid any sudden pressure changes in the circuit where you install the  

 

  component.

• The components must be fixed properly, using, where available, the applicable  

  Camozzi brackets so that the device remains fixed even when the regulator   

  operates at high frequency or in the presence of strong vibrations.

• Protect the TC pressure regulator from shock danger and from the external action  

  of mechanical components.

• In the presence of strong vibrations provide special devices / systems that can  

  reduce the effect on the component.

• When the component has been installed ensure that all pipes are properly    

  connected.

• Tightening torque of the fastening screw: 0.4 ÷ 0.7 Nm

Made in Italy

93-7522-0099 

rev.B

This product is in compliance with the requirements stated in the following standards and/or 

technical specifications:

- EN ISO 4414:2010 Pneumatic fluid power 

- General rules and safety requirements for systems and their components

Max inlet pressure

10 bar

Range of regulated pressure

0-0,5 / 0-2 / 0-3 / 0-4 bar

Fluid

oxygen, air, inert gas

Ambient temperature

-5 ÷ 50 °C

Mounting

in-line (in any position)

in a dedicated sub-base

in a specific seat (see drawing)

Port size IN (1) / OUT (2)

G 1/8 (only with sub-base)

Exhaust

without relieving

1  General safety instructions

6 Use limitations

7 Maintenance

8 Ecological informations

4 Use

5 Use with sub-base or specific seat

2 General characteristics and use conditions

3 Mounting and installation

Seat for regulator cartridge:

Regulation screw (

A

)

Regulation screw (

A

)

P

 

OUT

2

P

 

OUT

2

B

B

D

C

P

 

IN

1

P

 

IN

1

Reviews: