Operation and maintenance instructions
Series PRE proportional pressure regulator
IO-Link version
5000030186
Ver. 03
8
6.
General characteristics and conditions of use
General characteristics and conditions of use
PRE1
PRE2
Reference standards
CE; RoHs
Materials
Body: Aluminum Cover: Technopolymer Seal:NBR and FKM
Assembly position
Any
Overall dimensions
L = 50 mm; W = 50 mm; H = 140 mm
L = 50 mm; W = 50 mm; H = 185 mm
Weight
350gr circa
630gr circa
Medium and its quality
Filtered and non-lubricated compressed air of class 7.4.4 according to
ISO 8573.1. Inert gases and oxygen only for OX1 versions.
Maximum free flow rate
(Pin 10 bar)
Measured at ±5% of Preg
Pout 6 bar: 1.100 l/min ANR (PRE104)
Pout 4 bar: 1.200 l/min ANR (PRE104)
Pout 6 bar: 4.500 l/min ANR (PRE238)
Pout 4 bar: 5.200 l/min ANR (PRE238)
Maximum system
pressure drop
50 cc/min
10 cc/min
Maximun inlet pressure
(refer to coding table)
2 bar (B) 5 bar (E) 11 bar (D); (G) and (F)
Regulated pressure range
0 - 1 bar (0-14,5 PSI)(B) 0,05 - 10,3 bar (0,72-150 PSI)(D)
0,05 - 6 bar (0,72-87 PSI)(F) 0,03 - 4 bar (0,43-58 PSI) (E)
0,05 - 7 bar (0,72-101,5 PSI) (G)
Number of ways
3
Ambient temperature
0 ÷ 50 °C
Protection class
IP65 (according to EN 60529)
Open-type (according to UL 61010)
Pneumatic ports
Standard version: G1/4, 1/4 NPTF
Manifold version: G1/4; 1/4 NPTF
Standard version: G1/4, G3/8
Manifold version: G1/4
Vibrations sine
According to EN 60068 part
2-6:2009-11 (table B.1
)
Frequency range: 10-500Hz
Displacement 0-peak: 0,75mm or 100 m/s
2
Number of cycle: 10
Continuous shock
According to DIN EN
60068-2-27:2010-02 (table
A.1)
Peak acceleration: 150 m/s
2
Duration: 11ms
Pulse shape: half sine
Electric port
M12 4 Pin Male A-key
Input signal setpoint
IO-Link
Electrical power supply
24Vdc ±10%