Camlogic MN-03 Installation And Maintenance Download Page 2

REFERENCE  FIGURES

R80

ø125

149,4

138

ø1/2" Gas

ø180

ø180

13,2

40

25

100

123

78,2

n°4  equidistant  ø8,5  holes

ELECTRICAL  WIRING

Pic.3

The  conductors  forming  the  signal  carrying  cable  connected  to  the  microswitch  (Pic. 1)
must  have  an  adequate  cross-section  so  that  the  current  density,  in  each  conductors,

2

is  no  higher  than  4 A/mm . One  of  these  is  used  only  for  the  earthing  of  the  level  gauge.
The  cross-section  of  the  conductors  must  also  be  adequate  in  relation  to  the  overall
lenght  of  the  cable  used  to  avoid  drop  in  voltage  along  it,  over  the  values  prescribed
by  the  regulations  on  the  subject.
It  is  likewise  recommended  to  use  flexible  cables  with  an  adequate  outside  diameter
for  the  fair-leads  used  (not  supplied),  to  ensure  a  perfect  seal  of  the  cable  clamp
on  the  signal  carrying  cable.
For  connections  to  the  microswitch  terminals  use  eyelet  cable  terminals.
The  membrane  level  gauge  

MN-03

  has  two  1/2"  Gas  cable  inputs.  If  one  of  these  is

not  used,  it  must  be  closed  with  the  supplied  PVC  plug.

CAUTION:  there  is  a  screw  inside  the  casing,  near  the  right-hand  cable  input,  whose
position  is  marked  by  the  ground  symbol  (Pic. 3),  and  it  is  used  for  the  earthing  of
the  membrane  level  gauge.  This  screw  must  be  connected  to  the  yellow-green  conductor  (only  green  for  the  USA)
of  the  signal  carrying  cable.  The  ground  connection  of  the  membrane  level  gauge,  through  the  yellow-green  conductor,

Instructions  Manual  No. 00122  12.04  -  Rev. 00

All  the  informations  contained  in  this  manual  is  confidential  and  no

part  of  it  may  be  disclosed  without  written  authorization  from  

CAMLogic

.

This  manual,  even  after  the  sale  of  the  level  gauge,  is  lent  and  remains  the  property  of  the  Manufacturer.

-

MAINTENANCE

CAMLogic

  membrane  level  gauge  

MN-03

  needs  no  routine  maintenance.

A possible extraordinary maintenance is limited to the replacement of parts that have deteriorated through use.

GARANZIA

CAMLogic

,  in  addtion  to  the  terms  of  the  supply  contract,  guarantees  its  products  for  a  period  of  twenty-four  (24)  months

from  the  date  of  shipment.  This  warranty  is  expressed  only  in  the  repair  or  replacement  free  of  charge  of  parts  that,
after  careful  examination  by  the  Manufacturer,  turn  out  to  be  defective.
Warranty,  excluding  all  liability  for  direct  or  indirect  damage,  is  considered  to  be  restricted  to  only  defects  in  materials
and  has  no  effect  if  the  parts  returned  turn  out  to  have  been  anyhow  dismantled,  tampered  with  or  repaired  by  anyone
other  than  the  manufacturer.  Warranty  likewise  excludes  damage  deriving  from  negligence,  carelessness,  bad  or  improper
use  of  the  membrane  level  gauge,  or  from  bad  handling  by  the  operator  and  faulty  installation.
Warranty  is  moreover  forfeit  if  non-genuine  spare  parts  have  been  used.
A  returned  membrane  level  gauge  

MN-03

,  even  if  under  warranty,  must  be  shipped  carriage  free.

00122  12.04  -  Rev. 00

is  compulsory.

EU

   DECLARATION  OF  CONFORMITY

The  manufacturer  

CAMLogic

  declares, under  its  own  responsability,  that  the  product  

MN-03/.

  answers to  the  requisites  of

the  European  Directive  2014/34/EU.  Declaration  of  Conformity:  

CL 12  ATEX  0320

.

Marking:       II  3 D  Ex  tc  IIIC  T85°C  Dc
The  application  zone  is  the  22.