Camlogic MN-03 Installation And Maintenance Download Page 1

Installation  and  Maintenance  Rules  for:

MN-03, MN-03/V

Membrane  level  gauges  MN-03

R

S.a.s. di Guazzetti Giovanni e C.

COSTRUZIONI  MECCANICHE  ELETTRICHE

Via dell'Industria 12 - 12/A - 42025 CAVRIAGO - RE - Italy

Tel.: 0522/942641 - 0522/941172

www.camlogic.it

e-mail: [email protected]

STANDARD  FEATURES

The   membrane   level   gauge  

MN-03

   is   built   in   compliance   with   the   regulations   in   force   in   the   European   Union   and

specifically  with:
- Die-cast  aluminium  casing  UNI 5076.  IP65  protection.

-

MN-03

  with  rubber  membrane,  max.  temp.  inside  storage  bin  60°C.

-

MN-03/V

  with  Viton  membrane,  max.  temp.  inside  storage  bin  80°C.

PACKING

SAFETY  RULES

All  the  appropriate  safety  precautions  must  be  taken  when  electrically  operated  equipment  is  used,  in  order  to  reduce
the  risk  of  fire  outbreaks,  electric  shock  and  injuries  to  persons.

The   membrane   level   gauge  

MN-03

   can   be   supplied   in   single   packing

multiple  packing  or  palletized.  To  handle  the  supply,  if  palletized,  use  a
fork-lift  truck  or  transpallet.  In  the  case  of  single  packing,  the  weight  is
under  5 Kg  and  can  be  handled  manually.
If  the  level  gauge  has  to  be  stored  for  a  long  time  (up  to  two  years  at
most),  the  storage  environment  must  have  an  ambient  temperature  of  no
less  than  +5°C  with  relative  humidity  no  higher  than  60%.

-
-

-

-
-
-

-
-

Keep  the  work  zone  clean  and  orderly.  Accidents  are  more  likely  to  occur  in  untidy  areas  and  environments.
Before  beginning  to  work,  make  sure  that  the  level  gauge  is  in  perfect  condition.  Damaged  or  broken  parts  must  be
repaired  or  replaced  by  competent  personnel  authorized  by  the  Manufacturer.
All  verifications,  inspections,  cleaning  and  maintenance  operations,  part  changes  and  replacements  must  be  carried  out
with  the  level  gauge  disconnected.
It  is  absolutely  forbidden  for  children,  unauthorized  and/or  inexpert  persons  to  touch  or  use  the  level  gauge.
Make  sure  that  the  earthing  is  efficiently  connected  when  the  instrument  is  installed.
Periodically  check  to  be  sure  that  the  cable  is  in  a  perfect  condition  and  replace  it  if  any  damage  is  discovered.
This   operation   must   be   carried   out   only   by   competent    and   authorized   personnel.   Only   use   extension   cables   of   the

Protect  the  cable  against  high  temperatures,  lubrificants  and  sharp  edges.  Do  not  twist  or  knot  the  cable.
Do  not  allow  children  or  unauthorized  personnel  to  touch  the  cable.

DESCRIPTION

- Normally  open  contact

- Common  contacs

- Normally  closed  contact

Pic.1

Membrane   level   gauge  

MN-03  

operates   safely   and   reliably   and   are

used  to  check  and  automate  conveying  system  with  storage  silo.
Their   operation   is   based   on   the   transmission   of   pressure   to   which
the  membrane  is  subject  by  a  powdery  or  granular  product.
The   pressure   applied   to   the   membrane   activates   a   microswitch   with
switch  contacts  (Pic. 1).  The  tension  of  the  membrane,  thus  the  actuation
force  of  the  microswitch,  can  be  adjusted  by varying the  compression
of the internal spring  (Pic. 2).

Pic. 2

The  membrane  level  gauge  

MN-03  

can  be  used  slanted  up  to  45°

from  the  vertical  position. Therefore  it  should  be  installed  on  the  vertical
walls  of  the  silo  or  container.
The  device  is  provided  with  a  pressure  filter  that  ensures  the  right
atmospheric  balance  inside  the  casing.  The  filter  allows  air  from  the
outside  environment  to  pass  inside  the  casing,  thus  preventing  the
formation   of   pressures   that   could   obstruct   the   movement   of   the
membrane  and,  consequently,  the  operation  of  the  microswitch.

INSTALLATION

The  level  gauge  is  mounted  on  the  external  wall  of  the  silo  by  means
of   a   counterflange   whose   size   correspondes   to   the   dimensions   of
the  

MN-03

  (see  REFERENCE  FIGURES).

+

-

- Use  contact  capacity:   10 A.  a  250 V.c.a.
- Operating  temperature:      from  -20  to  +60 °C.

permitted  type,  and  marked.

II 3 D Ex tc IIIC T85°C Dc