11
Version 1.5
English
10
Ice Master
®
E-Series
English
7)
Turn your pumps back off. Once your
pumps are no longer running tighten the
pressure regulators
clockwise
until they
are tight.
Operating the Sprayer
GETTING STARTED
5)
Switch on all three pumps, using the
solenoid controller.
6)
Once the pumps are running, check
that water is recirculating freely back
into the tank. Once liquid is circulating
back into the tank, your re-circulation
test is complete.
GETTING STARTED
8)
If you wish to fill the tank from an
external source, hook up your fill hose to
the external fill valve and make sure the
valve is open. Then start the pump at
your liquid source and it will pump liquid
straight into the tank.
9)
To use the spray gun, ensure the
valve to the hose reel is in the open
position.
Operating the Sprayer
Pro Tip:
When you are spraying using all three pumps, you will
be outputting approximately 10 gallons per minute.
Important Note:
You will need to keep your pressure regulators tightened,
for maximum pressure. You can expect approximately 20-
30 psi from your center pump and approximately 10-15 psi
from your left and right pumps.
10)
To clean your filter during use, twist
the red insert clockwise and pull it out.
This will engage a valve in the filter body
to stop liquid from draining out the line.