33
Technical data - EU 2015 (1185)
15.
Technical data - EU 2015 (1185)
Technical documentation for individual room heaters for solid fuels - Regulation (EU) 2015/1185 supplementary to
Directive 2010/30/EU:
Name and address of the manufacturer: Camina & Schmid Feuerdesign und Technik GmbH & Co. KG
Harmonised standards: EN 13229 :2001/A2 :2004/AC:2007
Other applied standards or technical specifications: none
Indirect heating function (yes/no): no
Models
(Fuel: logs,
moisture content ≤ 25 %)
Test reports
Direct
thermal
output
Room heating
annual efficiency
ŋs 5 %
ŋ
s
[x %]
Emissions at nominal heat output (*)
EEI (*)
PM
OGC
CO
NO
x
[x] mg/Nm3 (13 % O2)
Lina 45
RRF - 29 15 4505-1
7.0 kW
65.0
75.0
40
120
1500
200
106
Lina 45 GT
RRF - 29 10 2332
5.5 kW
65.0
75.0
40
120
1500
200
103.3
Lina 55
RRF - 29 10 2333
7.0 kW
65.0
75.0
40
120
1500
200
109
Lina 67
RRF - 29 15 4500-1
9.0 kW
65.0
75.0
40
120
1500
200
107.5
Lina 73
RRF - 29 06 1074
9.0 kW
65.0
75.0
40
120
1500
200
103.4
Lina 87
TÜV Süd R-809066-4
10.0 kW
65.0
75.0
40
120
1500
200
106.7
Lina 87/70
TÜV Süd R-848363-1
19.0 kW
65.0
75.0
40
120
1500
200
103.3
Lina 100
RRF - 29 06 1074
10.0 kW
65.0
75.0
40
120
1500
200
103.4
Lina 120
RRF - 29 10 2334
10.0 kW
65.0
75.0
40
120
1500
200
106.6
(*) PM = particulate matter, OGC = organic gaseous compounds, CO = carbon monoxide, NO
x
= nitrous oxides, EEI = Energy Efficiency Index
Type of thermal output / Room temperature control
One-stage thermal output, no room temperature control: no
Two or more stages, no room temperature control: yes
Specific precautions for assembly, installation or maintenance