Technical data

12. 

Technical data

Operation with closed fireplace according to EN 13229

Lina GT

4545 s/h

4551 s/h

4557 s/h

Lina

4545 s/h

4551 s/h

4557 s/h

Lina

4580 h

Lina

5545 s/h

5551 s/h

5557 s/h

Lina 

5580 h

Lina

6745 s/h

6751 s/h

6757 s/h

Lina

6780 h

Nominal heat output

kW

5

7

7

7

7

9

9

Thermal output range

kW

2.4–5.4

3.4–7.8

3.4–7.8

3.4–7.4

3.4–7.4

3,2-10,9

3,2-10,9

Room heat output

kW

5

7

7

7

7

9

9

Heat distribution: 

through the viewing window

 %

30

25

25

30

30

30

30

Heat distribution: 

convective output

 %

70

75

75

70

70

70

70

Suitable for multiple flue connections to the chimney

Flue gas connector

Ø in mm

160

180

180

180

180

180

200

Combustion air connector

Ø in mm

125

125

125

125

125

125

125

SMR combustion control

recommended free cross-section

1

Supply air (cm

2

)

840

1260

1260

1180

1180

1520

1520

Recirculation air (cm

2

)

700

1050

1050

980

980

1260

1260

Combustion air requirement

m³/h

20

28

28

28

28

36

36

Recommended quantity of wood, approx.

kg

2.0

3.0

3.5

3.0

3.5

4.0

4.3

Recommended quantity of wood with NHK, approx.

kg

---

5.5

---

5.5

---

7.0

---

Recommended quantity of wood with heat storage 

system, approx.

kg

4.0

5.5

---

5.5

---

5.5

5.5

Recommended length of logs

cm

33

33

33

33

33

33

33

Fuel conversion

kg/h

3.7

5.1

5.1

5.1

5.1

5.3

5.3

Minimum distance to the fire box 

(in accordance with TR OL 2006, version 2010)

mm

800

800

800

800

800

800

800

Minimum distance to the insulation 

(in accordance with TR OL 2006, version 2010)

mm

50

70

70

70

70

90

90

Insulation thickness 

(with a wall that does not need to 

be protected) (based on SILCA® 250KM)

mm

60

60

60

60

60

60

60

Weight

kg

180-220

190-230

250

200-240

260

220-260

280

Fuel

Type

Wood

Wood

Wood

Wood

Wood

Wood

Wood

Triple v

alues 

with nominal

 

heat output

Flue gas mass flow

g/s

4.7

7.5

7.5

6.4

6.4

9.1

9.1

Flue gas temperature

°C

340

330

330

260

260

320

320

Required delivery pressure

Pa

12

12

12

12

12

12

12

Triple v

alues 

for

 connecting 

cer

amic flues 

 

(w

ood used as 

fuel)

Firing power

kW

13.2

18.2

---

18.2

---

18.2

---

Flue gas mass flow 

g/s

11.9

14.7

---

15.1

---

16.3

---

Flue gas temperature 

upstream of the connecting surface

°C

347

337

---

335

---

335

---

Required delivery pressure at the flue 

gas connector

Pa

15

15

---

15

---

15

---

Combustion air requirement

m³/h

46.3

63.9

---

63.9

---

66.3

---

Recommended flue length

2

m

3.5

3.5

3.5

1.7

---

3.5

3.5

Emission  v

alues 

W

ood fuel

CO 

- based on 13  % O₂

mg/Nm³

< 1250

< 1250

< 1250

< 1250

< 1250

< 1250

< 1250

Dust 

- based on 13 % O₂

mg/Nm³

< 40

< 40

< 40

< 40

< 40

< 40

< 40

Efficiency

 %

> 78

> 78

> 78

> 80

> 80

> 78

> 78

Minimum heat-emitting surface

3

 

(based on closed design)

3.6

3.6

3.6

3.6

3.3

4.2

4.0

Ecodesign Regulation in accordance with (EU) 2015/1185

Energy efficiency class in accordance with (EU) 2015/1186

 

 

Energy efficiency index (EEI)

103.2

103.7

103.7

109.0

109.0

103.4

103.4

Declaration of Performance

No.

LE29102332

LE29061106

LE29061106

LE29102333

LE29102333

LE29061074

LE29061074

possible  connected  equipmen

t

Top mounted heat exchanger

---

---

---

---

Hot air top-mounted element

---

---

---

---

Heat exchanger

---

---

---

---

Efficiency with connected equipment

 %

---

> 80

---

> 80

---

> 80

---

Hot water top-mounted element (HWAR R)

---

---

---

---

s = hinged door, h = guillotine door, TV = tunnel version

The specified waterside output was determined under test conditions. The achievable output can vary 

depending on the flue liner, quantity of wood and pump assembly used.

1

 The calculation was based on “TR OL 2006, edition 2010 – Table 17: Free cross-section in cm² for grille or 

opening tile based on the thermal output for air heating” with the preferred air velocity of 0.75 m/s. Supply air 

grille 240 cm2 / kW, recirculation air grille 200 cm² / kW.

2

 The information regarding flue lengths is a recommendation and based on the 

calculation in accordance with TR OL 2022 chapter 15. The calculation is based on a 

medium-heavy design and a flue ratio of 360 cm².

4

 With the exception of height 80 cm

3

 Average value based on the storage time. Depending on the material properties 

and the construction thickness. 

Mean specific heat distribution = approx. 500 W / m²

Summary of Contents for Lina 4545 s

Page 1: ...Fireplace insert OPERATING INSTRUCTIONS LINA 45 120 LINA TV 45 120...

Page 2: ...na 5557 h Lina 5580 h Lina 6745 h Lina 6751 h Lina 6757 h Lina 6780 h Lina 7345 s Lina 7351 s Lina 7357 s Lina 7363 s All rights reserved The reprinting reproduction and dissemination either in whole...

Page 3: ...551 s s Lina TV 4557 s s Lina TV 5545 s s Lina TV 5551 s s Lina TV 5557 s s Lina 7351 h Kristall Lina 7363 h Kristall Lina 8745 h Lina 8751 h Lina 8757 h Lina 8770 h Lina 10045 h Lina 10051 h Lina 100...

Page 4: ...llation instructions heat protective glove tensioning key depending on model front fireplace glass cleaner stove paint long adjustable feet depending on model Lina TV 6745 h s Lina TV 6751 h s Lina TV...

Page 5: ...s 15 3 3 1 Recommended residual moisture level 15 3 3 2 Heating behaviour of wood 15 3 3 3 Calorific value of the wood 16 3 3 4 Correct drying and storage 16 3 3 5 Drying time 16 3 4 Wood briquettes 1...

Page 6: ...gulations These operating instructions are intended to help you use this heating technology safely and properly Compliance with these operating instructions will ensure your safety and is the prerequi...

Page 7: ...the safe use of this product and indicates possible dangers It provides information on how dangers can be avoided 1 4 Important information Information indicated by the i symbol provides useful infor...

Page 8: ...n accordance with EU 305 2011 From your dealer importer or E mail info camina schmid de Website www camina schmid de leistungserklaerungen D C Fig 1 Serial plate No Type A CE marking as per EC No 765...

Page 9: ...lace inserts are not in operation 1 8 5 Multiple flue connections Refer to chapter 12 Technical data regarding the suitability of the fireplace inserts if more than one fireplace is connected to the s...

Page 10: ...ransition times e g autumn or spring or in bad weather e g fog strong wind etc Keep the door closed when the fireplace is in operation Make sure that doors with self closing function always need to be...

Page 11: ...cian chimney sweep and check the chimney for damage 2 Determine the cause of the chimney fire with the technician chimney sweep and rectify it 1 11 Fire protection Comply with all state building regul...

Page 12: ...m A B Fireplace insert Fig 4 Protection of combustible components in the radiation range in front of the fire box opening Lina Lina TV Description A Ventilated radiation protection B Parts made of com...

Page 13: ...Rear hinged door Further information on the appliance types can be found in chapter 12 Technical data Example of construction other types are similar 2 2 Installation of Lina Lina TV guillotine door C...

Page 14: ...od ash produced remains in the firebox without ash collector and with appliances with ash box it is collected under the firebox 2 5 Heating technology and environment Wood is an energy source that is...

Page 15: ...mperature as quickly as possible to over 500 C Only then is the carbon in the wood converted into carbon dioxide rather than carbon monoxide a high combustion chamber temperature is also necessary for...

Page 16: ...especially during the colder and wetter months of the year 3 3 5 Drying time A minimum of one year is a guideline time for drying softwood e g coniferous wood birch and a minimum of two years for har...

Page 17: ...start up report at the end of these operating instructions The technician needs to hand over to the operator all the technical documents on the appliance and all accessory parts for the safe operatio...

Page 18: ...ontrolled ventilation of no more than 4 Pa of under draught towards the outside at the location of the fireplace insert When simultaneously operating extraction systems e g ventilation systems extract...

Page 19: ...ombustion air is guaranteed Refer to chapter 7 1 3 Removing ash for the procedure 5 3 2 Recommended wood arrangement The cross section of the wood logs and arrangement of the wood in the firebox is cr...

Page 20: ...minute so that excess oxygen flows in and prevents the ceramic glass window from fogging up when it is heated up Refer to chapter 12 Technical data for the recommended loading capacity 5 5 Phases of...

Page 21: ...this position when the fireplace insert is not in use 5 6 Combustion on ash grate The wood rests on the ash grate with appliances with an ash grate The ash is collected in a ash box underneath which c...

Page 22: ...ith the instructions for use Service Box The cleaning intervals depend on the operating time heating habits and the quality of the fuel Adjust the frequency of cleaning to these conditions Do not imme...

Page 23: ...e top of the door by swivelling them This secures the door and it can no longer be raised The locking tongues B C are located under the cover of the guillotine door A B A Fig 27 Locking tongue closed...

Page 24: ...king properly again B A Fig 32 Right locking tongue open Components A Locking tongue on left B Locking tongue on right 7 1 5 Rear tilting door in cleaning position Lina TV Kristall model 1 Open lock b...

Page 25: ...8 Combustion air setting Check whether the combustion air lever is in the fully open position 5 5 Combustion air from the room Open the window and switch off any extraction system 1 8 5 5 1 External c...

Page 26: ...ll breaks in operation and longer pauses check the heating and exhaust paths specifically the chimney for blockages and remove blockages before starting up the fireplace again Check the entire firepla...

Page 27: ...sure Pa 12 12 12 12 12 12 12 Triple values for connecting ceramic flues wood used as fuel Firing power kW 13 2 18 2 18 2 18 2 Flue gas mass flow g s 11 9 14 7 15 1 16 3 Flue gas temperature upstream o...

Page 28: ...d delivery pressure Pa 12 12 12 12 12 12 12 Triple values for connecting ceramic flues wood used as fuel Firing power kW 15 19 8 18 2 Flue gas mass flow g s 14 5 16 7 14 7 Flue gas temperature upstrea...

Page 29: ...livery pressure Pa 12 12 12 12 12 12 Triple values for connecting ceramic flues wood used as fuel Firing power kW 18 2 18 2 19 8 Flue gas mass flow g s 15 1 29 6 16 7 Flue gas temperature upstream of...

Page 30: ...ik GmbH Co KG Supplier s model ID Lina 55 s h Lina TV 55 s s h s Energy efficiency class A Direct heat output kW 7 0 Indirect heat output kW Energy efficiency index EEI 109 0 Fuel energy efficiency at...

Page 31: ...s Lina 8770 h Energy efficiency class A A Direct heat output kW 10 0 19 0 Indirect heat output kW Energy efficiency index EEI 103 2 103 2 Fuel energy efficiency at nominal heat output 78 1 78 1 Infor...

Page 32: ...E F G 2015 1186 6 0 kW ENERGIA ENERGIJA ENERGY ENERGIE ENERGI A A A A A A 80 A 60 A 40 A 20 Lina GT 7363 h A A A B C D E F G 2015 1186 9 0 kW ENERGIA ENERGIJA ENERGY ENERGIE ENERGI A A A A A A 80 A 6...

Page 33: ...5 0 75 0 40 120 1500 200 103 3 Lina 55 RRF 29 10 2333 7 0 kW 65 0 75 0 40 120 1500 200 109 Lina 67 RRF 29 15 4500 1 9 0 kW 65 0 75 0 40 120 1500 200 107 5 Lina 73 RRF 29 06 1074 9 0 kW 65 0 75 0 40 12...

Page 34: ...f the complaint by the specialist company is possible with prior written agreement and clarification of cost with the manufacturer Warranty period and limitation period Depending on the product the wa...

Page 35: ...unless they are directly related to damage under warranty Reimbursement for indirect or direct consequential damag es Reimbursement of indirect or direct consequential damages e g air freight disposal...

Page 36: ...36...

Page 37: ...r invoice and this warranty certificate for our warranty to come into force Please note our General Terms and Conditions of Sale Please also note that this certificate must carry a registration number...

Page 38: ...rage stone systems BA_Lina_LinaTV_45_120_V9_2022_07_78 4668 3101_EN Camina Schmid 2022 07 100 Natural stone systems Hydronic technology Gas fireplace inserts Our product range Camina Schmid Feuerdesig...

Page 39: ...le wall multi wall outer wall stainless steel Combustion air supply Operating mode room air composite external combustion air Combustion air conduit Diameter mm Extended length m Bend Ventilation syst...

Page 40: ...rmal discharge safety device fitted easily accessible poss inspection opening Expansion tank Appliance protected by its own expansion tank Cap valve fitted System pressure checked and adjusted bar Pip...

Reviews: