Camfil PM1 Tracker Instruction Manual Download Page 5

5

Camfil - Clean air solutions

•  PM 1NDEX DEFINITION

The PM 1ndex will give an indication of your Indoor Air Quality and allows you to improve it. 
With 50 years of experience in the Indoor Air (and data collection) industry and based on WHO* guidelines 

on PM2,5 (annual mean exposition: 10 µg/m

3

), Camfil have defined an Air Quality Index which ranges from 

1 (Very Good) to 5 (Very bad).

PM 1ndex

Air Quality

PM1 (µg/m

3

)

Typical Environment

5

Very bad

> 8.3

Industrial or no ventilation

4

Bad

< 8.3

Bad ventilation / filtration or no filtration

3

Standard

< 3.9

Standard office

2

Good

< 1.4

Good ventilation and filtration

1

Very Good

< 0.60

Pure air with air cleaner

Sources :

•  Guideline WHO* on PM2.5: 10µg/

m

3

•  Ambient Air Particle Mass Size Distribution defined in ISO16890: PM1 represents 70 to 80% of PM2,5 value. 
•  Hundreds of measurements in Indoor Environments thanks to Camfil Software: Air Image. 

Note: Indoor Air Quality varies due to sources/activity/humans, etc. Always keep in mind that Indoor Air 

Quality varies: PM 1ndex mode will provide a mean value for 15 minutes in order to cut off peaks and 

erratic values. Don’t touch or move the unit during the PM 1ndex measurement.

4.  REALTIME MODE

This mode will continuously display different parameters.
It will allow you to see the number and mass of PM1 in a particular situation. Temperature and Relative 

Humidity are also displayed.

IAQ measurement

: Number of particles (0,5 to 1 µm) and PM1  

value in µg/m

3

Wellness measurement

: Temperature and Relative Humidity

 

•  Values of Temperature and Relative Humidity are displayed continuously
•  Particle counting is displayed every minute (first display after 1 minute)
•  Hold button to stop measurement
•  Pressing the Selection Button will allow you to switch from one screen 

to the other. The measurement will go on for 10 minutes (otherwise 

the measurement stops)

*WHO: World Health Organisation

Summary of Contents for PM1 Tracker

Page 1: ...Clean air solutions INSTRUCTION MANUAL PM1 TRACKER Make the invisible visible measure and improve your IAQ ...

Page 2: ... Very fine particles combustion nanoparticules bacteria virus small spores BECAUSE THEY CAN PENETRATE DEEP INTO THE HUMAN BODY Passage into the bloodstream alveoli and to the brain INDOOR AIR CAN BE 50X MORE UNSAFE THAN OUTDOOR AIR We breathe 15 kg of air per day Indoor environment can be 50 times more polluted We spend 90 of our time indoor More than 25 000 000 particles with each breath PM1 ARE ...

Page 3: ...d PM1 value mass Temperature Relative Humidity Monitoring this function is not activated yet 1 INTRODUCTION The different PM1 Tracker modes are accessible via the Selection Button on the side of the unit press once to change between modes or hold the button 2s to validate the mode of choice The Selection Button is used to select different modes validate and select options In certain modes an autom...

Page 4: ...e PM 1ndex measurement displays the Indoor Air Quality after 15 minutes of data collection During this time The Operational Indicator LED will blink in yellow After every minute an intermediate result is displayed in the Information Panel A gauge at the bottom of the Information Panel indicates the status of the test Hold the Selection Button to stop the measurement Press the Selection Button once...

Page 5: ...vironments thanks to Camfil Software Air Image Note Indoor Air Quality varies due to sources activity humans etc Always keep in mind that Indoor Air Quality varies PM 1ndex mode will provide a mean value for 15 minutes in order to cut off peaks and erratic values Don t touch or move the unit during the PM 1ndex measurement 4 REALTIME MODE This mode will continuously display different parameters It...

Page 6: ...on ANNEX BATTERY If the unit is off press the Selection Button once to check battery status If the Operational Indicator LED blinks in green the PM1 Tracker can be used If the Operational Indicator LED blinks in red you must charge the battery Note if no flash appears charge the battery On the Information Panel an indication of the battery charge is displayed The PM1 Tracker will automatically shu...

Page 7: ...7 Camfil Clean air solutions ...

Page 8: ...articles gases and emissions These solutions are used glob ally to benefit human health increase performance and reduce energy consumption in a wide range of air filtration applications Our 26 manufacturing plants six R D sites local sales offices and 3 800 employees provide service and support to our customers around the world Camfil is headquartered in Stockholm Sweden Group sales total more tha...

Reviews: