Camfil CC400 Technical Manual Download Page 16

Air Cleaner 

Consealed CC400 manual, 

Ver. 001 

Oct 2018 

    TECHNICAL MANUAL

 

  Air Cleaner CC400 Concealed

 

 

 

16

 

19.Air Cleaner

 

system 

 
 
 

 

Two

 

air

 

purifiers

 

work

 

together

 

in

 

a

 

cleaning

 

system. 

In

 

compartment

 

1,

 

the

 

incoming

 

air

 

creates

 

overpressure.

 

This

 

means

 

that

 

the

 

air,

 

after

 

it

 

has

 

passed

 

through

 

the

 

air

 

purifier,

 

is

 

transported

 

to

 

compartment

 

2.

 

There,

 

the

 

air

 

is

 

sucked

 

through

 

another

 

Air Cleaner,

 

which

 

further

 

raises

 

the

 

air

 

quality.

 

You

 

can

 

also

 

use

 

various

 

effective

 

filters

 

in

 

the

 

air

 

purifiers

 

to

 

control

 

the

 

air

 

quality.

 

In

 

this

 

instance,

 

a

 

class

 

H13

 

filter

 

is

 

used

 

in

 

compartment

 

1,

 

where

 

the

 

contaminated

 

incoming

 

air

 

enters.

 

This

 

method

 

is 

used

 

in

 

premises

 

used

 

for

 

production,

 

in

 

air

 

locks

 

as

 

well

 

as

 

in

 

other

 

environments. 

 

 

Over

 

pressure. 

Exactly

 

as

 

in

 

the

 

example

 

above,

 

overpressure

 

is

 

created

 

when

 

the

 

air

 

is

 

purified

 

and

 

enters

 

the

 

compartment.

 

By

 

doing

 

this,

 

a

 

thoroughly

 

controlled

 

indoor

 

environment

 

is

 

achieved

 

in

 

the 

space

 

in

 

question.

 

This

 

is

 

useful

 

in

 

processes

 

such

 

as

 

those

 

involving

 

installation,

 

food,

 

electronic

 

installation,

 

and

 

other

 

sensitive

 

production

 

units. 

 

 

 

Under

 

pressure. 

In

 

this

 

example,

 

the

 

air

 

is

 

sucked

 

from

 

the 

compartment

 

and

 

purified

 

before

 

it

 

is

 

discharged

 

into

 

the

 

room.

 

Air Cleaner

 

also

 

makes

 

it

 

possible

 

to

 

clean

 

the

 

air

 

many

 

times

 

before

 

allowing

 

it

 

to

 

be

 

released,

 

in

 

order

 

to

 

achieve

 

increased

 

control

 

over

 

the

 

air

 

quality.

 

Under

 

pressure

 

is

 

used,

 

for

 

example,

 

on

 

building

 

sites,

 

and

 

in

 

industries

 

and

 

places

 

where

 

a

 

small

 

dirty

 

production

 

area

 

in

 

large 

premises 

 

 

Cleaning

 

zone

 

in

 

open

 

premises. 

In

 

this

 

example,

 

the

 

air

 

is

 

purified

 

in

 

the

 

Air 

Cleaner

 

unit

s

 

HEPA

 

filter.

 

Then

 

it

 

passes

 

through

 

the

 

pipe

 

along

 

the

 

ceiling,

 

where

 

air 
Is

 

discharged

 

from

 

the

 

holes

 

along

 

the

 

wall.

 

The

 

purified

 

air

 

thus

 

creates

 

a

 

sort

 

of

 

curtain

 

that

 

divides

 

the

 

room

 

into

 

two

 

zones;

 

one

 

with

 

higher

 

quality

 

air

 

and

 

one

 

with

 

lower

 

quality

 

air. 

Summary of Contents for CC400

Page 1: ...TECHNICAL MANUAL Air Cleaner CC400 Concealed Air Cleaner Consealed CC400 manual Ver 001 Oct 2018 1 ...

Page 2: ...ESIGN 8 10 1 CONSTITUENT STANDARD COMPONENTS 8 11 TRANSPORT AND UNPACKAGING 8 10 2 AIR FLOW DETAILS 9 12 TAKING INTO OPERATION 10 12 1 POSITIONING 10 12 2 SYSTEM INTEGRATION 10 12 3 4 5 6 ELECTRICAL CONNECTION 11 13 MEASSURING POINT FOR PA 12 14 AIR CLEANER AND THE ENVIRONMENT 13 14 1 AIR CLEANER FILTERS AND THE ENVIRONMENT 13 15 MAINTENANCE 13 16 INSTRUCTIONS FOR REPLACING AIR CLEANER FILTERS 13 ...

Page 3: ...first few sections also give some technical specifications After these there are illustrated texts about the various parts that make up the Air Cleaner Concealed The user manual also includes details of safety procedures associated with the use of the machine 3 Version history Version Date Signature Altered 001 See approval Initial version 4 Identification plate All Air Cleaner Concealed type mach...

Page 4: ...mportant 4 Before using your Air Cleaner Concealed air it is important that you as the user read this user manual read the fan instructions and follow the safety instructions in both documents 7 Technical specifications External dimensions vertical model Height 313 mm Width 1112 mm Depth 327 mm Weight 21 9 kg including new filters Filter weight 6 5 kg 1 pcs XLT and 1 pcs x Hepa 13 7 1 Fan specific...

Page 5: ...ng mounting If the Air Cleaner Concealed is to be mounted in a ceiling or on a wall the following points must be borne in mind 1 Ceiling mounting the unit must be so mounted that there is no risk of trucks and similar colliding with it 2 The ceiling or wall must be able to take a load of 88 kg 3 Always install with safety switch to disconnect the power supply during services or maintenance 4 Only ...

Page 6: ...TECHNICAL MANUAL Air Cleaner CC400 Concealed Air Cleaner Consealed CC400 manual Ver 001 Oct 2018 8 2 Mounting drawings 6 ...

Page 7: ...ection may only be carried out by an appropriately qualified electrician Wall outlets must also be installed by an appropriately qualified electrician 5 Accessories filters spare parts etc used with the Air Cleaner Concealed must be approved by Camfil AB Guarantee undertakings cease to apply if the foregoing is not respected Please contact Camfil AB for the correct accessories 6 Do not cover inlet...

Page 8: ...tandard version the air purifier is supplied with the following components One Air Cleaner Concealed unit with 2pcs of circular take off Ø 250 mm These have rubber gaskets and can be connected to Spiro type circular ducts One protective Lock for filter replacement Filters for the chosen purpose User manual Fan instructions from the fan supplier If anything is missing or if you require further info...

Page 9: ...here is the HEPA filter This is a unique environment friendly absolute filter It is so efficient that air must pass three times through the ventilation system to achieve the same level of air purification as it does in a single circulation through the Air Cleaner The extremely large filter surface increases both service life and filter efficiency Further increases of the HEPA EPA filter s service ...

Page 10: ...e 50 cm around outlet and inlet 12 2 System integration When connecting ventilation ducts to the Air Cleaner Concealed these items must be secured to support their own weight There is not recommended to connect more than 8 meters of 250mm circular ventilation ducts on outlet and inlet of the unit 12 3 Electrical connection Electrical connection must be carried out by an appropriately qualified ele...

Page 11: ...8 TECHNICAL MANUAL Air Cleaner CC400 Concealed 12 4 Electrical Connection 1 phase EC fan NB Only appropriately qualified electricians may carry out work on or in this machine 11 Electrical connection with Controller Card fuse holder and RS485 connector ...

Page 12: ...TECHNICAL MANUAL Air Cleaner CC400 Concealed 13 Measuring points for Pa or filter efficiency tests Filter efficiency Pressure drop A Before filter A B Pre filter B After Pre filter B C HEPA filter C After HEPA filter A C Pressure both filters 12 A B A C ...

Page 13: ...lease contact your local authority or distributor for advice on correct care 15 Maintenance If necessary the Air Cleaner Concealed can be cleaned using a mild cleaning agent Before cleaning always switch offthemachine andpull outtheelectricalconnector 16 Instructions for replacing Air Cleaner Concealed filters WARNING When handling used filters personal protective equipment such as protective glov...

Page 14: ...move it NB Hold the top cover firmly Alternatively secure it during removal 3 Grip the upper edge of the bag filter frame pull it towards you And put the filter into a plastic bag 4 Release the screw counter clock wise which keeps the HEPA filter in place 5 Take a firm grip the sling which is around the HEPA filter and pull it towards you 14 6 Lift the filter carefully out Scrapped filters must be...

Page 15: ...hine must not be placed in extremely high or low temperatures The guarantee does not cover problems arising through carelessness negligence Remember that the classification covers the machine only and not the filters For information about filters contact your local Camfil office 18 EU provisions governing the product This product complies with EU standards as per the machine directive 2006 42 EC t...

Page 16: ...enters the compartment By doing this a thoroughly controlled indoor environment is achieved in the space in question This is useful in processes such as those involving installation food electronic installation and other sensitive production units Under pressure In this example the air is sucked from the compartment and purified before it is discharged into the room Air Cleaner also makes it possi...

Page 17: ...d with each other With the aid of a calibrated particle counter the quantity of particles in the air can be examined By subscribing to this service you will as a customer always have a particle counter in place connected to a computer which monitors the indoor environment When an abnormal particle distribution is identified or in cases of other suspected problems we perform an analysis with a scan...

Page 18: ...wer stations Camfil Farr is a global company with 29 subsidiaries 23 production plants and an extensive network of agents in Europe the Americas and the Asia Pacific region Air Cleaners Air Cleaners is synonymous with high efficiency purification energy savings and almost silent operation Unlike all other air purifiers on the market our HEPA filters offer a degree of purification that can eliminat...

Reviews: