MC-III™ EXP Flow Analyzer
Section 3
Entering the Slave Address
The slave address is a setting used in Modbus
®
communications. It is a number that ranges from 1 to 65535,
excluding 252 to 255 and 64764. If the Modbus
®
request message contains the matching address, the
device will respond to the request. In network arrangements, the device must have a unique slave address.
For more information about Modbus
®
communications, refer to the protocol manual section. If Modbus
®
communications are not used, leave the slave address at the factory setting (1).
To Enter the Slave Address:
Enter the Output menu.
Press OUTPUT MENU.
OUTPUT
MENU
00000000
...
00000000
...
00000000
...
00000000
...
Locate the Slave Address setting.
Press ENTER until the words “Slave
Address” appear in the lower display.
SAVE
ENTER
00000000
...
The rightmost digit in the top display
will begin blinking.
Enter the slave address.
(range: 1 to 65535, excluding 252 to
255 and 64764)
Press UP ARROW until the correct
digit is displayed.
TEST
Then press LEFT ARROW to select
the next digit to the left.
Repeat using UP and LEFT arrows to
enter all remaining digits.
LOG
Press ENTER.
SAVE
ENTER
The Baud Rate menu prompt will appear immediately following the entry of the slave address. See
Entering
the Baud Rate
below for the baud rate entry procedure.
Entering the Baud Rate
The baud rate is the number of bits per second that are on the serial port. This setting must match the setting
of the master device polling the MC-III EXP or the serial port. This only applies to the Modbus
®
communica-
tions; if Modbus
®
communications are not used, leave the baud rate at the factory setting (9600).
To Enter the Baud Rate:
Enter the Output menu.
Press OUTPUT MENU.
OUTPUT
MENU
Locate the Baud Rate setting.
Press ENTER repeatedly until the
words “Baud Rate” appear in the
lower display.
SAVE
ENTER
115200
Enter the baud rate.
Press UP ARROW until the correct
baud rate is displayed.
TEST
Press ENTER. “SAVING” will appear
in the bottom display.
SAVE
ENTER
Summary of Contents for NUFLO MC-III EXP
Page 1: ...NUFLO TM MC III EXP Flow Analyzer User Manual Manual No 9A 50165003 Rev 06 Valves Measurement ...
Page 18: ...12 Section 1 MC III EXP Flow Analyzer ...
Page 35: ...29 MC III EXP Flow Analyzer Section 2 ...
Page 46: ...40 Section 3 MC III EXP Flow Analyzer ...
Page 81: ...75 MC III EXP Flow Analyzer Section 4 ...
Page 93: ...87 MC III EXP Flow Analyzer Section 5 Figure 5 17 Dropdown menu for exporting log data ...
Page 94: ...88 Section 5 MC III EXP Flow Analyzer ...
Page 105: ...99 MC III EXP Flow Analyzer Section 6 ...
Page 114: ...A 9 MC III EXP Flow Analyzer Appendix A ...
Page 121: ...B 7 MC III EXP Flow Analyzer Appendix B ...
Page 123: ...C 2 Appendix C MC III EXP Flow Analyzer ...
Page 141: ...D 18 Appendix D MC III EXP Flow Analyzer ...
Page 143: ......