IMPORTANT SAFETY INSTRUCTIONS 

-

 

Follow all instructions. 

-

 

Do not use this apparatus near water. 

-

 

Clean only with dry cloth. 

-

 

Do not block any ventilation openings. 

-

 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two 
blades with one wider than the other. A grounding type plug has two blades and a third grounding 
prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit 
into your outlet, consult an electrician for replacement of the obsolete outlet. 

-

 

Protect the power cord from being walked on or pinched particularly at plugs, convenience 
receptacles, and the point where they exit from the apparatus. Only use attachments/accessories 
specified by the manufacturer. 

-

 

Unplug this apparatus during lightning storms or when unused for long periods of time. 

-

 

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been 
damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or 
objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not 
operate normally, or has been dropped. 

-

 

To ensure proper ventilation always make sure there is at minimum  four inches (101.6mm) of space 
behind the rear of the apparatus. The ventilation should not be impeded by covering the ventilation 
openings with items, such as newspapers, tablecloths, curtains, etc. 

-

 

Do not impede ventilation by placing objects on top of the apparatus which extend past the rear edge 
of its cabinet. No open flame sources, such as lighted candles, should be placed on the apparatus. 

-

 

The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such 
as vases, shall be placed on the apparatus. 

 

WARNING: 

To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. 

The AC plug is the mains disconnect. The plug should remain accessible after installation. 
 

WARNING: 

Always make sure proper load is connected before operating the amplifier. Failure to do so 

could pose a shock hazard and may result in damage to the amplifier. 
 

WARNING (EU)

: Permission from the Supply Authority is needed before connection. Do not expose 

amplifier to direct sunlight or extremely high temperatures. Always insure the amplifier is properly 
grounded. Always unplug AC power cord before changing fuse, tubes or removing chassis. Use only 
same type and rating when replacing fuse. Avoid direct contact with heated tubes. Keep amplifier away 
from children. To avoid damaging your speakers and other playback equipment, turn off the power of all 
related equipment before making the connections. Do not use excessive force when handling buttons, 
switches and controls. Do not use solvents such as benzene or paint thinner to clean the unit. Always 
connect to an AC power supply that meets the power supply specifications listed on the rear of the unit. 
Make certain grounding conforms to local standards. 
 

YOUR AMPLIFIER IS LOUD! EXPOSURE TO HIGH SOUND VOLUMES MAY CAUSE 
PERMANENT HEARING DAMAGE! 
 
Your Cameron Amplifier is a professional instrument. Please treat it with respect and operate it 
properly. 

Summary of Contents for CCV-100

Page 1: ...Cameron A M P L I F I C A T I O N Cameron CCV 100 Owner s Manual Version 1 1 ...

Page 2: ...s loop is also equipped with an adjustable send level knob This knob adjusts the send level to help compensate for decreased increased signals The loop is located after the preamp and before the power amp An effects loop is a must if you plan on using time based effects like chorus or delay Use send going to the effects unit and return from the effects unit Midi The CCV is equipped with midi switc...

Page 3: ...low gain no clipping and the amp will be loud and clean To the left is mid gain clipping To the right is max gain clipping Keep in mind that as you add gain clipping you are clipping the entire signal so the volume will drop this is normal Just adjust the volume up or down to compensate for any changes Bass This knob controls the lower frequencies Turn it down to lower the bass turn it up to incre...

Page 4: ...encies Turn it down to lower the bass turn it up to increase the bass Middle This knob controls the mid range frequencies Turn it down to lower the mids turn it up to increase the mids The CCV naturally has a lot of mids so don t be afraid to set the knob below half way Treble This knob controls the high end frequencies Turn it down to lower the treble turn it up to increase the treble Gain 2 This...

Page 5: ...ne starting to degrade depending on how often it is used the power tubes will need to be properly biased in order to function correctly IF you are not sure how to bias an amp take it to a tech WARNING Amplifiers contain lethal voltages and care should be used when changing the power tubes All of the preamp tubes are 12AX7 ECC83 types All of the power tubes are EL34 6CA7 KT77 types Sample Settings ...

Page 6: ...Page 6 ...

Page 7: ...p of the apparatus which extend past the rear edge of its cabinet No open flame sources such as lighted candles should be placed on the apparatus The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vases shall be placed on the apparatus WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture The AC plu...

Page 8: ...Page 8 Contact Brad King Email Brad CameronAmplifiers com Direct 401 932 5464 Cameron Amplification 5419 Cleon Ave North Hollywood CA 91601 ...

Reviews: