Camera Corps SD-HD MiniZoom Operation Manual Download Page 3

 

SD-HD MiniZoom 

– Operation Manual 

 

SD/HD Minizoom V3 

Page 2 of 6 

                                         3/2/2013 

 

 
Remove power from the unit and set the rotary channel select switch and DIP switches back to their 
normal required settings. 
 
Next time power is applied to the Interface unit the camera will have the new format. 
 
The DIP switches on the top of the interface unit must also be changed for SD or HD modes. (Visible 
through the slot in the top panel). SW1 and 2 must OFF for HD and ON for SD. 
 

DIP SWITCH >   

HD           1080i /50 

OFF 

OFF 

OFF 

OFF 

HD           1080i /59.94 

ON 

OFF 

OFF 

OFF 

HD           720p/50 

OFF 

ON 

OFF 

OFF 

HD           720p/59.94 

ON 

ON 

OFF 

OFF 

SD       PAL(50)  16x9 

OFF 

OFF 

ON 

OFF 

SD       PAL(50)   4x3 

OFF 

OFF 

ON 

ON 

SD    NTSC(59.94) 16x9 

ON 

ON 

ON 

OFF 

SD    NTSC(59.94)  4x3 

ON 

ON 

ON 

ON 

 

Embedded Audio 

The Interface box has a female 

9 way ‘D’ connector on the side which allows up to four audio channels to 

be embedded into the output SDI data stream. 
 
The DIP switches on the top of the Interface Unit are used to turn the embedding on or off and to set the 
audio levels. DIP switch 6 turns the audio embedding on or off.  
 
The audio levels are set using DIP switches 4 & 5 as shown in the table below:- 

 

 

 
 
 
Audio 9 w ‘D’ Connections 

1. 

Common Screen 

2. 

Channel 1  

LEFT    

XLR pin 3 

3. 

Channel 1  

RIGHT  

XLR pin 3 

4. 

Channel 2  

LEFT    

XLR pin 3 

5. 

Channel 2  

RIGHT  

XLR pin 3 

6. 

Channel 1  

LEFT    

XLR pin 2 

7. 

Channel 1  

RIGHT  

XLR pin 2 

8. 

Channel 2  

LEFT    

XLR pin 2 

9. 

Channel 2  

RIGHT  

XLR pin 2 

 

Input Level Range 

Full Scale (0dBFS)  DIP Switch 4  DIP Switch 5 

Professional US 

+24dBu 

LEFT (Off) 

LEFT (Off) 

Professional European  +18dBu 

LEFT (Off) 

RIGHT (On) 

Consumer High (IHF) 

+12dBu 

RIGHT (On) 

LEFT (Off) 

Consumer Low 

+15dBu 

RIGHT (On) 

RIGHT (On) 

1          2         3         4         

2     3 
CH1L 

 2    3 
CH1R 

2     3 
CH2L 

 2     3 
CH2R 

Common 

Screen 

Summary of Contents for SD-HD MiniZoom

Page 1: ...SD HD MiniZoom Camera Operation Manual ...

Page 2: ... a balanced audio signal which can be sent over virtually unlimited distances down a normal microphone cable or CAT5 No DC continuity is necessary The rotary switch together with the left hand two DIP switches allow selection of up to 32 data ID s The right hand two DIP switches are used to select the length of the camera cable One switch provides equalisation for 10m of cable and the other for 20...

Page 3: ...e box has a female 9 way D connector on the side which allows up to four audio channels to be embedded into the output SDI data stream The DIP switches on the top of the Interface Unit are used to turn the embedding on or off and to set the audio levels DIP switch 6 turns the audio embedding on or off The audio levels are set using DIP switches 4 5 as shown in the table below Audio 9 w D Connectio...

Page 4: ...de the interface box must be changed to allow serial rather than the audio data input to be used Link 2 is connected to allow serial data inputs In the unconnected mode it is left on just one of the link pins Link 3 is moved to set either RS232 or RS422 style data inputs Both of these links are labelled showing their function on the PCB Note that serial baud rate is not selectable and must be 9600...

Page 5: ...vides groups 4 7 instead of 0 3 LK2 is used to change the data input from the standard audio data to either RS232 or RS422 data LK3 selects between RS232 and RS422 data Note that only 9600 baud is available for these inputs Appendix C Removing the Interface Box lid To access the links the lid of the interface box must be removed to access the PCB First remove the power from the unit Then remove th...

Page 6: ...ulti Camera ID s can be mixed for different channels if required MASTER SETUP Channel 1 ID 1 O P Level TX Baud 4 2400 This screen allows setting of the data level for the Audio Data O P Range 0 15 Default 4 for 1v pk to pk output for a single 600ohm load The TX Baud rate can be set here Note that both these settings apply to all channels not just the selected one This screen allows setting whether...

Page 7: ...Push operation in AWC Preset On for B W Off for Colour On for Auto Focus Off for Manual Power switching only operates with some systems 7 7 0 1 2 3db 0db 3db 6db 18db 1 1 10 000 Notes Shutter modes from 1 to 25 increase sensitivity but produce high levels of flicker Camera power switching is available with all camera models SO CC HV NY HDZ HD30 Off On Auto Analogue Control Operation Colour Gains C...