Press the ESC button or STOP button immediately in the event of any faults, malfunctions, strange noises or vibrations, or unexpected behaviour in the system.
GEARMOTORS WITHOUT R INTERFACE (control board 119RIR267)
Confi guration>
Motor settings>
Motor type
Generic
Number of motors
Motor test
Confi guration>
Wired safety devices>
CX input
CY input
CZ input
CK input
Confi guration>
Motor settings>
Limit-switch function
Slowdown in FA/FC (Default)
Select the parameter if both microswitches are used for slowdown.
Stop in FA, slowdown in FC
Select the parameter if the opening microswitch is used as a limit switch.
Input type FC/FA
N.O. (Default)
Select the parameter if both microswitches are normally open.
N.C. for FA input, N.O. for FC input
Select the parameter if the closing microswitch is normally open and the opening microswitch is normally closed.
Motor power
Minimum power [up to 120W]
Medium power (Default) [up to 200W]
Maximum power [more than 200W]
Confi guration>
Gate travel settings>
Opening approach space
Closing approach space
Set a value below 5%
Slowdown AST control
Deactivated (Default)
Confi guration>
Motor settings>
Travel calibration