21
- Manual
FA01796-IT -
04/2022 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
F44
Closing approach point for M2
0.5% to 25.0% (Default 8.0%)
F45
Reduce speed
OFF (Default)
1% to 50%
F46
Number of motors
2 (Default)
1
F50
Save data
OFF
ON (Run operation)
F51
Read data
OFF
ON (Run operation)
F56
CRP address
1 to 254 (Default 1)
F58
Confi gure maintenance
OFF (Default)
1X100 to 500X100
F63
RSE speed
2 = 4800 bps
3 = 9600 bps
4 = 14400 bps
5 = 19200 bps
6 = 38400 bps (default)
7 = 57600 bps
8 = 115200 bps
F72
Limit-switch function
OFF = Deactivated
1 = Opening limit-switch and closing limit-switch
2 = Slowdown (Default)
3 = Opening limit-switch, closing slowdown
F73
Input type FC/FA
0 = N.O. (Default)
1 = N.C.
2 = N.C. for FA input, N.O. for FC input
F83
Removing obstacles
OFF = Inversion caused by obstacle (Default)
ON = Remove obstruction
Summary of Contents for ZLX24MA
Page 87: ...3 FA01796 RU 04 2022 CAME S p A A B ZL19N ZLJ24...
Page 88: ...4 FA01796 RU 04 2022 CAME S p A...
Page 90: ...6 FA01796 RU 04 2022 CAME S p A ZLX24 120 230 V AC...
Page 91: ...7 FA01796 RU 04 2022 CAME S p A ZL19N L1T L2T THERMAL PROT 120 230 V AC L N ZL19N...
Page 92: ...8 FA01796 RU 04 2022 CAME S p A ZLX24 120 230 V AC...
Page 94: ...10 FA01796 RU 04 2022 CAME S p A 1 2 3 4 5 2 7 6 RG58 1 2 3 3P 4 7 BUS...
Page 95: ...11 FA01796 RU 04 2022 CAME S p A 1 2 3 10 11 E E3 5...
Page 99: ...15 FA01796 RU 04 2022 CAME S p A 1 ESC ESC 2 3 ENTER ENTER ESC...
Page 108: ...24 FA01796 RU 04 2022 CAME S p A ON OFF ON ENTER 1 2 Enter 3 F50 F51...
Page 109: ...25 FA01796 RU 04 2022 CAME S p A E1 1 E2 2 E3 E4 E7 E9 E10 E11 E12 E13 E15 E17 E18 E24 E25...
Page 110: ...26 FA01796 RU 04 2022 CAME S p A...
Page 111: ...27 FA01796 RU 04 2022 CAME S p A...