background image

13

A

ll t

h

e d

at

a a

n

d i

n

fo

rm

at

io

n c

o

n

ta

in

ed h

er

ei

n

 i

s c

o

n

si

d

er

ed

 s

u

b

je

ct to c

h

an

g

e a

t a

n

y t

im

e a

n

d a

t o

u

r d

is

cr

et

io

n

ENGLISH

 

 

In its premises, CAME CANCELLI AUTOMATICI S.p.A. implements an Environmental Management System certifi ed in 

compliance with the UNI EN ISO 14001 standard to ensure environmental protection.

Please continue our efforts to protect the environment—which CAME considers one of the cardinal elements in the development 
of its operational and market strategies—simply by observing brief recommendations as regards disposal:

 

DISPOSAL OF PACKAGING – The packaging components (cardboard, plastic, etc.) are all classifi able as solid urban waste 

products and may be disposed of easily, keeping in mind recycling possibilities.
Prior to disposal, it is always advisable to check specifi c regulations in force in the place of installation.

PLEASE DISPOSE OF PROPERLY!

 

PRODUCT DISPOSAL – Our products are made up of various types of materials. Most of them (aluminium, plastics, iron, 

electrical wires, etc.) may be disposed of in normal garbage collection bins and can be recycled by disposing of in specifi c re-
cyclable material collection bins and disposal in authorized centres. Other components (electrical boards, remote control batteries, 
etc.), however, may contain polluting substances. They should therefore be removed and given to qualifi ed service companies for 
proper disposal.
Prior to disposal, it is always advisable to check specifi c regulations in force in the place of disposal.

PLEASE DISPOSE OF PROPERLY!

7 Demolition and disposal

MANUFACTURER’S DECLARATION OF CONFORMITY

Pursuant to annex II B of the Machinery Directive 98/37/EC 

 

CAME Cancelli Automatici S.p.A.

 

via Martiri della Libertà, 15

 

31030 Dosson di Casier - Treviso - ITALY

 

tel (+39) 0422 4940 - fax (+39) 0422 4941

 

internet: www.came.it - e-mail: [email protected] 

Declares under its own responsibility that the equipments for automatic garage doors and 
gates listed below:

… comply with the National Law related to the following European Directives and to the 
applicable parts of the following Standards.

98/37/CE - 98/79/CE 

M

ACHINERY

 D

IRECTIVE

 

98/336/CEE - 92/31/CEE  E

LECTROMAGNETIC

 

COMPATIBILITY

 D

IRECTIVE

73/23/CEE - 93/68/CE 

L

OW

 V

OLTAGE

 D

IRECTIVE

89/106/CEE  

C

ONSTRUCTION

 

PRODUCTS

 D

IRECTIVE

EN 13241-1   

EN 12635 

 

EN 61000-6-2 

EN 12453 

 

EN 12978 

 

EN 61000-6-3  

EN 12445 

 

EN 60335-1   

EN 60204-1

IMPORTANT WARNING!

Do not use the equipment specifi ed here above, before completing the full installation

In full compliance with the Machinery Directive 98/37/EC

MANAGING DIRECTOR

Mr. Andrea Menuzzo

8 Manufacturer’s warranty

 

Reference code to request a true copy of the original: DDF B EN G001 ver.1.0

ZG6 ELECTRONIC COMMAND BOARD

Intelligent Security & Fire Ltd.

Summary of Contents for ZG6

Page 1: ...ZG6 AUTOMAZIONE PER CHIUSURA INDUSTRIALE INSTALLATION MANUAL COMMAND BOARD BASIC FOR BARRIERS WITH 230V MOTOR I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 2: ...l or the push button Other selectable functions Automatic closure The automatic closure timer self powers at the end stop in opening The set time can be adjusted and is also subject to modifications due to the intervention of additional safety features This does not happen following a complete stop command or if there be a power cut Immediate closure The bar lowers automatically after the vehicle ...

Page 3: ... 63 4 4 4 4 2 2 6 43 IS 12 6 3 11 1 5 9 8 7 Black Brown Brown Black Blue Red Orange White Black Red 13 10 2 5 White Red 4 14 Blue Violet Orange Grey Series connected accessories flashing dome signals the bar in motion lighted cord signals the bar closed or in motion it turns off only if the bar is at an end stop and opens Optional accessories bar open light marks the position of opening of the bar...

Page 4: ...ength of cable 20 30 m 230V 2F power supply line FROR CEI 20 22 CEI EN 50267 2 1 3G 1 5mm 3G 2 5mm 3G 4mm 230V motor 3G 1mm 3G 1 5mm 3G 2 5mm 230V courtesy cycle light 3G 0 5mm 3G 1mm 3G 1 5mm 24V power supply accessory 2 x 0 5mm 2 x 0 5mm 2 x 1mm 24V pilot light 2 x 0 5mm 2 x 0 5mm 2 x 1mm 24V in motion output 2 x 0 5mm 2 x 0 5mm 2 x 1mm Safety contacts 2 x 0 5mm 2 x 0 5mm 2 x 0 5mm N O N C contr...

Page 5: ...n Black Blue G2081 G2081I Orange Grey Blue Violet 5 4 Installing the electrical card 1 Unscrew the four mounting screws or three in the case of the G4041 of the cover of the container located on the upper part of the automation 2 Insert the card into the container and fasten it with the screws supplied 3 Connect the terminal boards of the transformer housed in the container to the command board Co...

Page 6: ...n motion and in closing IF NOT USED IF NOT USED 10 11 E6 TS 1 2 3 4 7 C1 C5 U V W FC FA F VS CT L2T L1T I N T E R B L O C C O N L M 10 E6 2 4 DIP DIP Condenser 5 5 Electrical connections 230V a c power supply 230V a c motor Stop pushbutton N C Open pushbutton N O Command pushbutton see dip switch 2 in function selections Contact N C of reopening during closing 24V A C max 30W supply accessories Co...

Page 7: ...urn dip switch 8 to ON to carry out the test IMPORTANT when carrying out the safety test function contacts N C if not used on the relative dip switches see functions selection p 8 5 6 Photoelectric cells performance test 5 7 Gearmotor end stop connection Gearmotor end stop assembly already connected for installation on the left hand side seen from inside For right hand installation reverse FA FC o...

Page 8: ...N Safety test function to check photoelectric cell efficiency page 7 activated 8 OFF deactivated 9 OFF Encoder activated for obstacle detection 9 ON deactivated 10 ON Enables 10 E6 output with moving function 10 ON Enables 10 E6 output with moving and closing function 5 12 Operation counter Counts the number of operations displayed with the 8 LED to zero out the count position the dip 1 to OFF if ...

Page 9: ...egister the code at the tenth pulse a double beep will confirm that registration has occurred AF board Mother board TOP QUARZATI SERIES Read the three steps below before beginning installation procedures prepare the radio board paragraph 6 1 procedure for codifying the transmitter paragraph 6 2 memorizing the code on the command board paragraph 6 3 6 1 Prepare the radio board AF 6 Installation pro...

Page 10: ... T2622M T3022M P1 CH1 P2 CH2 P3 CH3 P4 CH4 P1 CH1 P2 CH2 P1 CH1 P2 CH3 P1 CH3 P2 CH2 P1 CH1 P2 CH4 P1 CH3 P2 CH4 1 Code P1 CH1 P2 CH2 2 Code P3 CH1 P4 CH2 The first encoding operation must be carried out whilst keeping the jumpers po sitioned for channels 1 and 2 as per fig A see fig B for any subsequent settings on different channels I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 11: ...T314M 0 0 0 0 C set code only P1 CH1 P2 CH2 P3 CH3 P4 CH4 TOP T432S T432SA T434MA T432NA T434NA see instructions on pack TAM T432 T434 T438 TAM432SA see instruction sheet inside the pack TFM T132 T134 T138 T152 T154 T158 see instruction sheet inside the pack CAME AT01 AT02 AT04 see instruction sheet inside the pack of AF43SR circuit card CAME TCH 4024 TCH 4048 see instructions on pack TOUCH SERIES...

Page 12: ...ashing LED Lit LED Radiofrequency board 6 3 Memorizing the code on the command board 1 Keep the PROG key pressed on the base card the signal LED will flash 2 Insert the inspection door and close it 1 After making the adjustments and settings from the command board insert the lid of the container and close it with the screws 6 4 Mounting the lid 3 Insert the protection dome on the upper part of the...

Page 13: ...ntain polluting substances They should therefore be removed and given to qualified service companies for proper disposal Prior to disposal it is always advisable to check specific regulations in force in the place of disposal PLEASE DISPOSE OF PROPERLY 7 Demolition and disposal MANUFACTURER S DECLARATION OF CONFORMITY Pursuant to annex II B of the Machinery Directive 98 37 EC CAME Cancelli Automat...

Page 14: ...6 06 CAME CANCELLI AUTOMATICI CAME UNITED KINGDOM LTD UNIT 3 ORCHARD BUSINESS PARK TOWN STREET SANDIACRE NOTTINGHAM NG10 5BP U K Tel 0044 115 9210430 Fax 0044 115 9210431 I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Reviews: