background image

13

A

ll t

h

e d

at

a a

n

d i

n

fo

rm

at

io

n c

o

n

ta

in

ed h

er

ei

n

 i

s c

o

n

si

d

er

ed

 s

u

b

je

ct to c

h

an

g

e a

t a

n

y t

im

e a

n

d a

t o

u

r d

is

cr

et

io

n

ENGLISH

 

 

In its premises, CAME CANCELLI AUTOMATICI S.p.A. implements an Environmental Management System certifi ed in 

compliance with the UNI EN ISO 14001 standard to ensure environmental protection.

Please continue our efforts to protect the environment—which CAME considers one of the cardinal elements in the development 
of its operational and market strategies—simply by observing brief recommendations as regards disposal:

 

DISPOSAL OF PACKAGING – The packaging components (cardboard, plastic, etc.) are all classifi able as solid urban waste 

products and may be disposed of easily, keeping in mind recycling possibilities.
Prior to disposal, it is always advisable to check specifi c regulations in force in the place of installation.

PLEASE DISPOSE OF PROPERLY!

 

PRODUCT DISPOSAL – Our products are made up of various types of materials. Most of them (aluminium, plastics, iron, 

electrical wires, etc.) may be disposed of in normal garbage collection bins and can be recycled by disposing of in specifi c re-
cyclable material collection bins and disposal in authorized centres. Other components (electrical boards, remote control batteries, 
etc.), however, may contain polluting substances. They should therefore be removed and given to qualifi ed service companies for 
proper disposal.
Prior to disposal, it is always advisable to check specifi c regulations in force in the place of disposal.

PLEASE DISPOSE OF PROPERLY!

7 Demolition and disposal

MANUFACTURER’S DECLARATION OF CONFORMITY

Pursuant to annex II B of the Machinery Directive 98/37/EC 

 

CAME Cancelli Automatici S.p.A.

 

via Martiri della Libertà, 15

 

31030 Dosson di Casier - Treviso - ITALY

 

tel (+39) 0422 4940 - fax (+39) 0422 4941

 

internet: www.came.it - e-mail: [email protected] 

Declares under its own responsibility that the equipments for automatic garage doors and 
gates listed below:

… comply with the National Law related to the following European Directives and to the 
applicable parts of the following Standards.

98/37/CE - 98/79/CE 

M

ACHINERY

 D

IRECTIVE

 

98/336/CEE - 92/31/CEE  E

LECTROMAGNETIC

 

COMPATIBILITY

 D

IRECTIVE

73/23/CEE - 93/68/CE 

L

OW

 V

OLTAGE

 D

IRECTIVE

89/106/CEE  

C

ONSTRUCTION

 

PRODUCTS

 D

IRECTIVE

EN 13241-1   

EN 12635 

 

EN 61000-6-2 

EN 12453 

 

EN 12978 

 

EN 61000-6-3  

EN 12445 

 

EN 60335-1   

EN 60204-1

IMPORTANT WARNING!

Do not use the equipment specifi ed here above, before completing the full installation

In full compliance with the Machinery Directive 98/37/EC

MANAGING DIRECTOR

Mr. Andrea Menuzzo

8 Manufacturer’s warranty

 

Reference code to request a true copy of the original: DDF B EN G001 ver.1.0

ZG5 ELECTRONIC COMMAND BOARD

Summary of Contents for ZG5

Page 1: ...ZG5 INSTALLATION MANUAL AF ZG 5 COMMAND BOARD PLUS FOR BARRIERS WITH 230V MOTOR...

Page 2: ...ose the gate use the radio remote control or the push button Other selectable functions Automatic closure The automatic closure timer self powers at the end stop in opening The set time can be adjuste...

Page 3: ...d Optional accessories flashing dome signals the bar in motion lighted cord signals the bar closed or in motion it turns off only if the bar is at an end stop and opens bar open light marks the positi...

Page 4: ...Length of cable 10 20 m Length of cable 20 30 m 230V 2F power supply line FROR CEI 20 22 CEI EN 50267 2 1 3G 1 5mm 3G 2 5mm 3G 4mm 230V motor 3G 1mm 3G 1 5mm 3G 2 5mm 230V courtesy cycle light 3G 0 5m...

Page 5: ...nge White Condenser M Red Black Brown Brown Black Blue G2081 G2081I Orange Grey Blue Violet 5 4 Installing the electrical card 1 Unscrew the four mounting screws or three in the case of the G4041 of t...

Page 6: ...pen pushbutton N O Command pushbutton see dip switch 2 in function selections Contact N C of reopening during closing Pilot light indicating barrier open 24V 3W max Contact N O of immediate closing Op...

Page 7: ...carry out the test IMPORTANT when carrying out the safety test function contacts N C if not used on the relative dip switches see functions selection p 8 5 6 Photoelectric cells performance test EB EB...

Page 8: ...safety devices to termi nals 2 C1 if not used set the dipswitch to ON 8 ON Safety test function to check photoelectric cell efficiency page 7 activated 8 OFF deactivated 9 OFF Encoder activated for o...

Page 9: ...AF40 TOUCH Standard encoding procedure T262M T264M T2622M T302M T304M T3022M 1 assign a code also on file 2 connect encoding jumper J 3 register code 4 disinserire jumper J TOP TAM 0 0 Press P1 or P2...

Page 10: ...be carried out whilst keeping the jumpers po sitioned for channels 1 and 2 as per fig A see fig B for any subsequent settings on different channels TOP T262M T302M FIG A FIG B 0 0 0 0 T264M T304M 0 0...

Page 11: ...H1 CH2 CH3 CH4 TOP T434M T314M 0 0 0 0 C set code only P1 CH1 P2 CH2 P3 CH3 P4 CH4 TOP T432S T432SA T434MA T432NA T434NA see instructions on pack TAM T432 T434 T438 TAM432SA see instruction sheet insi...

Page 12: ...nd ing on the selection carried out on dip switches 2 CH2 Channel for direct commands with an accessory device radio control with combined barrier connection or with bush N B if desired simply repeat...

Page 13: ...tteries etc however may contain polluting substances They should therefore be removed and given to qualified service companies for proper disposal Prior to disposal it is always advisable to check spe...

Page 14: ...Cod 319T47 ver 1 3 06 06 CAME CANCELLI AUTOMATICI CAME UNITED KINGDOM LTD UNIT 3 ORCHARD BUSINESS PARK TOWN STREET SANDIACRE NOTTINGHAM NG10 5BP U K Tel 0044 115 9210430 Fax 0044 115 9210431...

Reviews: