ZG5

INSTALLATION MANUAL

AF

ZG 5

COMMAND BOARD PLUS FOR BARRIERS 

WITH 230V MOTOR

Summary of Contents for ZG5

Page 1: ...ZG5 INSTALLATION MANUAL AF ZG 5 COMMAND BOARD PLUS FOR BARRIERS WITH 230V MOTOR...

Page 2: ...ose the gate use the radio remote control or the push button Other selectable functions Automatic closure The automatic closure timer self powers at the end stop in opening The set time can be adjuste...

Page 3: ...d Optional accessories flashing dome signals the bar in motion lighted cord signals the bar closed or in motion it turns off only if the bar is at an end stop and opens bar open light marks the positi...

Page 4: ...Length of cable 10 20 m Length of cable 20 30 m 230V 2F power supply line FROR CEI 20 22 CEI EN 50267 2 1 3G 1 5mm 3G 2 5mm 3G 4mm 230V motor 3G 1mm 3G 1 5mm 3G 2 5mm 230V courtesy cycle light 3G 0 5m...

Page 5: ...nge White Condenser M Red Black Brown Brown Black Blue G2081 G2081I Orange Grey Blue Violet 5 4 Installing the electrical card 1 Unscrew the four mounting screws or three in the case of the G4041 of t...

Page 6: ...pen pushbutton N O Command pushbutton see dip switch 2 in function selections Contact N C of reopening during closing Pilot light indicating barrier open 24V 3W max Contact N O of immediate closing Op...

Page 7: ...carry out the test IMPORTANT when carrying out the safety test function contacts N C if not used on the relative dip switches see functions selection p 8 5 6 Photoelectric cells performance test EB EB...

Page 8: ...safety devices to termi nals 2 C1 if not used set the dipswitch to ON 8 ON Safety test function to check photoelectric cell efficiency page 7 activated 8 OFF deactivated 9 OFF Encoder activated for o...

Page 9: ...AF40 TOUCH Standard encoding procedure T262M T264M T2622M T302M T304M T3022M 1 assign a code also on file 2 connect encoding jumper J 3 register code 4 disinserire jumper J TOP TAM 0 0 Press P1 or P2...

Page 10: ...be carried out whilst keeping the jumpers po sitioned for channels 1 and 2 as per fig A see fig B for any subsequent settings on different channels TOP T262M T302M FIG A FIG B 0 0 0 0 T264M T304M 0 0...

Page 11: ...H1 CH2 CH3 CH4 TOP T434M T314M 0 0 0 0 C set code only P1 CH1 P2 CH2 P3 CH3 P4 CH4 TOP T432S T432SA T434MA T432NA T434NA see instructions on pack TAM T432 T434 T438 TAM432SA see instruction sheet insi...

Page 12: ...nd ing on the selection carried out on dip switches 2 CH2 Channel for direct commands with an accessory device radio control with combined barrier connection or with bush N B if desired simply repeat...

Page 13: ...tteries etc however may contain polluting substances They should therefore be removed and given to qualified service companies for proper disposal Prior to disposal it is always advisable to check spe...

Page 14: ...Cod 319T47 ver 1 3 06 06 CAME CANCELLI AUTOMATICI CAME UNITED KINGDOM LTD UNIT 3 ORCHARD BUSINESS PARK TOWN STREET SANDIACRE NOTTINGHAM NG10 5BP U K Tel 0044 115 9210430 Fax 0044 115 9210431...