5.3 Dimensions, axle bases and fastening holes
5.4 Minimum thicknesses and cables types
#!-%
MM
MM
MM
Connections
Cable Type
1<10 m Cable
Length
10<20 m
Cable Length
20<30 m Cable
Length
230V 2F power supply
FROR CEI 20-22
CEI EN 50267-2-1
3G 1,5mm²
3G 2,5mm²
3G 4mm²
230V 2F motors
4G 1mm²
4G 1,5mm²
4G 2,5mm²
230V fl ashing lamp
2 x 0,5mm²
2 x 1mm²
2 x 1,5mm²
230V cycle / courtesy lamps
3G 0,5mm²
3G 1mm²
3G 1,5mm²
Power for 24V accessories
2 x 0,5mm²
2 x 0,5mm²
2 x 1mm²
24V pilot lamp
2 x 0,5mm²
2 x 0,5mm²
2 x 1mm²
24V “in movement” output
2 x 0,5mm²
2 x 0,5mm²
2 x 1mm²
Safety contacts
2 x 0,5mm²
2 x 0,5mm²
2 x 0,5mm²
N.O./N.C. command keys
2 x 0,5mm²
2 x 0,5mm²
2 x 0,5mm²
End-stop
2 x 0,5mm²
2 x 1mm²
2 x 1,5mm²
Aerial connection (max 10m)
RG58
Encoder connection (max 30m)
Shielded cable 2402C 22AWG
N.B. The evaluation of the section of cables with lengths other than the ones stated in the table should be
considered according to the real absorption of the connected devices, in compliance with the prescriptions in
CEI EN 60204-1 standard.
Table dimensioning should be recalculated according to real absorption and distances for connections requi-
ring more than one charge (sequential) on the same line.