Page 1: ...ZE5 V 7 AUTOMAZIONE PER CHIUSURA INDUSTRIALE INSTALLATION MANUAL CONTROL PANEL FOR EMEGA SERIES...

Page 2: ...12978 UNI EN 954 1 CEI EN 60335 1 and UNI EN 12453 2 1 Destination 4 1 Components Electric Panel Power supply 230V 50 60 Hz Maximum power allowed 400 W Absorption at rest 150 mA Maximum power for 24V...

Page 3: ...Equipment and materials 5 2 Attrezzi e materiali Make sure all the necessary tools and materials are available to carry out the installation with the maxi mum safety in compliance with regulations in...

Page 4: ...s 2 x 0 5mm 2 x 0 5mm 2 x 1mm 24V pilot lamp 2 x 0 5mm 2 x 0 5mm 2 x 1mm 24V in movement output 2 x 0 5mm 2 x 0 5mm 2 x 1mm Safety contacts 2 x 0 5mm 2 x 0 5mm 2 x 0 5mm N O N C command keys 2 x 0 5mm...

Page 5: ...FA K E W V U F 5 5 Pre settings Fixing the Electric Board to the Ground Guide Art 001E001 and Ratiomotor Electric Connections E306 E456 Ratiomotor Use a 5 drill bit to bear a hole observing the dista...

Page 6: ...c courtesy lamp output max 60W 10 11 24V a c max 20W accessory power feed 24V 15W max electric lock connection set dip switch 9 to OFF 24V 3W max open door signalling pilot light set dip switch 9 to O...

Page 7: ...ns by keeping the key pressed key connected to 2 3 for opening and 2 7 for closing without including the remote control function 7 OFF Reopening during closure activated the safety device 2 C1 detects...

Page 8: ...ately 30 mm from the desired opening Rotate the cam until the micro switch can be inserted and tighten the screw in the cam Relock the ratiomotor Closing End Stop Set dip switch 8 to ON the LED indica...

Page 9: ...osing mode is deactivated and the thrust reduction function is automatically inserted the function is made active when the door is about to close The LED indicator will resume flashing after having pr...

Page 10: ...e opening end stop of a single motor WARNING WARNING ACCES ACCES LINE LINE A C T A C T ENC ENC 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 05 06 07 08 09 V1 V2 V3 05 06 07 08 09 V1 V2 V3 ZE7...

Page 11: ...ess P1 or P2 in sequence to record the code on the tenth impulse a double beep will confirm the memorisation has taken place Frequency MHz Board Transmitter FM 26 995 AF130 TFM FM 30 900 AF150 TFM AM...

Page 12: ...ent channels TOP T262M T302M FIG A FIG B 0 0 0 0 T264M T304M 0 0 0 0 0 0 T2622M T3022M P1 CH1 P2 CH2 P3 CH3 P4 CH4 P1 CH1 P2 CH2 P1 CH1 P2 CH3 P1 CH3 P2 CH2 P1 CH1 P2 CH4 P1 CH3 P2 CH4 1 Code P1 CH1 P...

Page 13: ...34 T438 TAM432SA See instructions sheet included in the package TFM T132 T134 T138 T152 T154 T158 See instructions sheet included in the package CAME AT01 AT02 AT04 See the instructions sheet included...

Page 14: ...terminals 1 2 Repeat encoder programming THE GARAGE DOOR REMAINS OPEN check the automatic closing function dip switch 1 check if control devices are functioning properly check if there is something o...

Page 15: ...ace of disposal PLEASE DISPOSE OF PROPERLY 9 Maker s statement Also they furthermore represent and warrant that the product s that are the subject of the present Declaration are manufactured in the re...