CAME ZC3C Installation Manual Download Page 3

L1T L2T

VS

CT

24 12      0

L1 L2

U

V

W

E E1 EX

10 11 TS

1

2

3

7

3P 4

5

2 C1 CX FC FA F

B1 B2

ON

11 12 13 14 15 16 17 18 19 20

ON

1 2 3 4 5 6 7 8 9 10

23

4

01

2

2

4

1

L1T

L2T

VS

FUSE

ACCESS.

315mA

LINE FUSE 5A

+ AUT.CL. -

+ PAR.OP. - 

+ OPER.TIME -

AF

CONTROL BOARD

ZC3

CH1

CH2

CLOSE

OPEN

1 2 3 4 5 6 7 8 9 10 11 12 

V1 V2 V3 V4 V5

04 05 06 07 08

CONTROL BOARD

1A

FUSE

1

2

13

5

6

12

7

8

10

11

4

14

3

9

CAME

18

15

17

16

CAME

APRE

CHIUDE

240 mm

215 mm

165 mm

320 mm

295 mm

p.

33

 - M

an

ua

l c

od

e: 

FA

0

0

6

9

2

-E

N
-E

N

 v

2

 

08

/2

01

6

 © C

A

M

E S

.p.

A

. - T

he d

ata a

nd i

nfo

rm

ati

on i

n t

hi

s m

an

ua

l m

ay b

e c

ha

ng

ed at a

ny time a

nd wit

ho

ut n

oti

ce

.

 Dimensions, centre distances and anchoring holes

8 Main components

 Warning! Before acting on the equipment, 

cut off the main power supply and disconnect 
the emergency batteries (if present).

 Connect the black wires protruding from 

the card onto condenser connectors.

1 Connecting 

terminals

2  5 A line fuse
3  1 A accessories fuse
4  24 V power on LED warning light
5  Working time adjuster trimmer
6  Automatic closing time adjuster trimmer
7  Partial opening adjusting trimmer
8  LED warning light
9  Code memorising buttons
10  Functions selector
11  Radio frequency card socket
12  Motor torque limiter
13  630 mA card fuse
14 Transformer
15 STOP button
16 CLOSE button
17 OPEN button
18 Safety block

Summary of Contents for ZC3C

Page 1: ...INSTALLATION MANUAL ZC3C CONTROL PANEL FOR 230 V GEAR MOTORS FA00692 EN English EN...

Page 2: ...on the container The card provides and controls the following functions automatic closing after an opening command partial opening for pedestrian passage obstacle detections when gate is not moving at...

Page 3: ...manual may be changed at any time and without notice Dimensions centre distances and anchoring holes 8 Main components Warning Before acting on the equipment cut off the main power supply and disconn...

Page 4: ...for continuity purposes of the protective circuit are fitted with extra insulation compared to other internal conductive parts Set up proper conduits and electric cable raceways making sure these are...

Page 5: ...e cover onto the hinges 6 After adjusting and setting secure the cover using the issued screws Electrical connections Single Phase 230 V AC motor Gearmotor Limit switches installed FA F Limit switch o...

Page 6: ...rning devices Cycle Courtesy lamp Contact rated for 230 V 60 W Max Cycle lamp_lights up the parking area and stays on from the moment the sliding gate starts opening unitl it is fully closed including...

Page 7: ...ocells sensitive edges and other devices that comply with EN 12978 regulations While the gate is closing opening the contact will invert movement until it is fully closed Dip 8 OFF 9 ON Contact N C fo...

Page 8: ...cting functions DIP switches 1 10 Key switch selector and or opening button N O contact Opening gate for pedestrian passage The opening time can be adjusted via the PART OPEN The automatic closing tim...

Page 9: ...SE FUSE ACCESS 315mA LINE FUSE 5A AUT CL PAR OP OPER TIME AF CONTROL BOARD ZC3 CH1 CH2 CLOSE OPEN 1 2 3 4 5 6 7 8 9 10 11 12 V1 V2 V3 V4 V5 04 05 06 07 08 CONTROL BOARD 1A FUSE 24 12 0 L1 L2 ON 11 12...

Page 10: ...i see instruction sheet in AF43SR radiofrequency card Activating the radio command Connect RG58 antenna cable to the apposite terminals Possible second channel output of the radio receiver N O contact...

Page 11: ...ONTROL BOARD ZC3 CH1 CH2 CLOSE OPEN CONTROL BOARD 1A FUSE 24 12 0 L1 L2 ON 11 12 13 14 15 16 17 18 19 20 ON 1 2 3 4 5 6 7 8 9 10 10 11 TS 1 2 3 3P 4 5 7 2 C1 CX FC FA F B1 B2 E D CH1 CH2 p 11 11 Manua...

Page 12: ...his to be one of the fundamentals in its market operations and development strategies Just follow these short disposal instructions DISPOSING OF THE PACKAGING The components of the packaging i e cardb...

Reviews: