background image

FA00526-EN – ver. 3.3.1 – 12/2016      

 

Power and control that the SYNC LED lights are flashing on the both circuit 
SADRIN TX and SADRIN RX. In the case where only the TX LED is 
blinking, check the connections of the synchronism. 

Test the barrier interrupting a pair of beams at a time making sure the 
ALARM LED is lit. 

After test complete program the desired operating mode as reported in the 
table below. 

Programming has been completed, if desired, turn off the LED with the appropriate jumper and close the 
barriers. 

FUNCTION 

DIP POSITION 

DELAY 

AND 

AND - ON 

500ms 

FAST - OFF 

FAST 

AND - OFF 

100ms 

FAST - ON 

NORMAL 

AND - OFF 

250ms 

FAST - OFF 

alarm LED ON 
me

alarm LED OFF 

Summary of Contents for SADRIN 205

Page 1: ...Installation manual BI205 BI205W BI410 BI410W BI615 BI615W BI820 BI820W BI825 BI825W FA00526 EN...

Page 2: ...n board the receiver will indicate the alarm status via an LED indicator and relay contact placed on the card The interlocking profile allows you to insert or remove the cover of polycarbonate without...

Page 3: ...If you need to reduce the length of profile cutting and taking care to avoid metal slag from falling onto electronic circuits 3 Insert the sqaure gasket in the cap up to the square to match 4 Insert...

Page 4: ...grooves present on the cap and on the cover to allow the passage of the cable from the outside of the barrier CABLE CASHED VIEWABLE CABLE Round grooves on the bottom for cable Grooves on the walls fo...

Page 5: ...e of rainwater that could accumulate inside the closing 9 Attach the whole structure to the wall you can make small adjustments both horizontally and vertically thanks to the holes located on the caps...

Page 6: ...nal blocks and seal the cable routing to prevent the entry of water and insects Make sure the screws are tight so that there is electrical contact between the board and the metal section that acts as...

Page 7: ...the barrier interrupting a pair of beams at a time making sure the ALARM LED is lit After test complete program the desired operating mode as reported in the table below Programming has been complete...

Page 8: ...relay you MUST link between the transmitter and the receiver SADRIN TX SADRIN RX the two wire synchronous sync TX to SincRX sync TX to sync RX NB Only for expansions is provided the switch The beam 1...

Page 9: ...to the negative of 13 8 VDC to all columns 6 TECHNICAL CHARACTERISTICS MODEL SADRIN 205 SADRIN 410 SADRIN 615 SADRIN 820 Max range outdoor Blak 15m White 5m Sinchronism wired Dual beam optical Yes wi...

Page 10: ...COMMERCIAL PRODUCT Came S p A Via Martiri Della Libert 15 IT 31030 DOSSON DI CASIER TV TEL 39 0422 4940 FAX 39 0422 4941 info came com www came com...

Reviews: