background image

FA00772M04

It

al

ia

no

 - M

an

ua

le 

FA

00

772

M

04

 - v

er

1

 - 0

5/

20

17 - © C

am

e S

.p

.A

.

I c

on

te

nu

ti d

el m

an

ua

le s

on

o d

a r

ite

ne

rs

i s

us

ce

tti

bi

li d

i m

od

ifi

ca i

n q

ua

ls

ia

si m

om

en

to s

en

za o

bb

lig

o d

i p

re

av

vis

o.

RICEVITORE UNIVERSALE

MANUALE DI CONFIGURAZIONE

PXWRXU

Summary of Contents for PXWRXU

Page 1: ...FA00772M04 RICEVITORE UNIVERSALE MANUALE DI CONFIGURAZIONE PXWRXU...

Page 2: ...riciclabili riportano simbolo e sigla del materiale I DATI E LE INFORMAZIONI INDICATE IN QUESTO MANUALE SONO DA RITENERSI SUSCETTIBILI DI MODIFICA IN QUALSIASI MOMENTO E SENZA OBBLIGO DI PREAVVISO LE...

Page 3: ...1 3 Associazione uscita 1 8 Apprendi Segnale radio Radiocomandi Configurazione tasti Uscita 1 8 Tempo impulso 1 15 Apprendi Segnale radio Sirena Apprendi Segnale radio IN OUT Filari Polarit ON OFF 12...

Page 4: ...Disabilitata Segnalazione IN OUT Nessuna Solo ingresso Solo uscita Tutte Supervisione SI NO Descrizione Apprendi Segnale radio IN OUT Filari Stato Abilitato Disabilitato Polarit ON OFF 12 V inserita 0...

Page 5: ...TO la segnalazione di allarme attiva con un ritardo definito dal menu IMPOSTAZIONI T ENTRATA Canale radio default 1 Scegliere il canale radio da associare all ingresso In presenza di pi ingressi sullo...

Page 6: ...diocomando da configurare 1 8 e definirne lo stato ABILITATO il radiocomando abilitato per essere utilizzato nell impianto DISABILITATO il radiocomando non abilitato per essere utilizzato nell impiant...

Page 7: ...a sirena radio ABILITATA la sirena abilitata per essere utilizzata DISABILITATA la sirena non abilitata per essere utilizzata nell impianto Abilitata la sirena ed eseguito l autoapprendimento lo stato...

Page 8: ...con figurati Mostra allarmi default SI Permette di abilitare o disabilitare la visualizzazione degli allarmi Gli eventi di allarme possono essere di tipo NC Stato lo stato di allarme viene resettato d...

Page 9: ...te ad un cambia mento di stato della centrale da disinserita a inserita o tramite l inserimento del codice utente e la pressione di uno dei tasti Mostra memoria guasti Mostra memoria guasti default SI...

Page 10: ...Utente Codici utente default 123456 Permette di modificare il codice di accesso dell utente Permette di impostare data e ora del ricevitore Con il parametro REGOLAZIONE possibile correggere lo sfasame...

Page 11: ...123456 di default e premere per confermare Eventi Mostra allarmi Mostra allarmi Permette di abilitare o disabilitare la visualizzazione dell ultimo allarme rilevato dall impianto di allarme Vengono ci...

Page 12: ...e l inserimento del codice utente Impostazioni Contrasto display Contrasto display Permette di regolare l intensit luminosa del display da 10 a 90 con intervalli di 10 Backlight timeout Backlight time...

Page 13: ...FA00772 EN CONFIGURATION MANUAL PXWRXU MULTI PURPOSE RECEIVER...

Page 14: ...h the laws in force in the country where the product is used The recyclable components are marked with a symbol and the material s ID marker THE DATA AND INFORMATION SHOWN IN THIS MANUAL ARE TO BE CON...

Page 15: ...u Radio Inputs Radio channel 1 3 Associate output 1 8 Learn Radio signal Remote controls Configure buttons Output 1 8 Impulse time 1 15 Learn Radio signal Siren Learn Radio signal Wired IN OUT Polarit...

Page 16: ...on Learn Radio signal Siren Status Enabled disabled IN OUT warning None Input only Output only All Supervision YES NO Description Learn Radio signal Wired IN OUT Status Enabled disabled Polarity ON OF...

Page 17: ...Sensor alarm PXWDT Sensor alarm PXWDTPI Sensor alarm PXWIRCE Sensor alarm PXWDTVE Sensor alarm PXWDTCL Sensor alarm PXWIRCB Input 1 Input 2 Sensor alarm PXWCOB01 PXWCOM01 Input 1 Input 2 REED contact...

Page 18: ...ociated with the remote control button Each time the button is pressed the chosen output changes status Status default ENABLED if learnt DISABLED if not learnt Select the remote control to be configur...

Page 19: ...efault None Enables the siren warning lights when the system is engaged input or disengaged output Status default ENABLED if learnt DISABLED if not learnt Manages the radio siren output ENABLED the si...

Page 20: ...ce the time set in the SETTINGS T RE STORE menu has lapsed e g shutter contact volumetric sensors etc To set the alarm events see the remote device manual These events are reset when the alarm stops b...

Page 21: ...efault 60 It allows you to adjust the display brightness from 10 to 90 in intervals of 10 Settings Display contrast Show fault memory default YES Enables or disables the fault memory view Show fault m...

Page 22: ...undergo during the day This adjustment is made in seconds and is decreased at the end of the day User codes default 123456 It allows you to change the user access code User codes Installer codes defa...

Page 23: ...an be deleted automatically when the input is activated or by entering the user code Show alarm memory Show alarms Enables or disables the last detected alarm view All of the alarms in progress are di...

Page 24: ...y daily clock drift which the receiver may undergo during the day This adjustment is made in seconds and is decreased at the end of the day Clock User codes It allows you to change the user access cod...

Page 25: ...FA00772 FR MANUEL DE CONFIGURATION PXWRXU R CEPTEUR UNIVERSEL...

Page 26: ...selon les normes en vigueur dans le pays o le produit est utilis Le symbole et le sigle du mat riau figurent sur les composants recyclables LES DONN ES ET LES INFORMATIONS CONTENUES DANS CE MANUEL SON...

Page 27: ...on sortie 1 8 Apprendre Signal radio Radiocommandes Configuration des touches Sortie 1 8 Dur e impulsion 1 15 Apprendre Signal radio Sir ne Apprendre Signal radio IN OUT Filaires Polarit ON OFF 12 V a...

Page 28: ...N OUT Aucune Entr e uniquement Sortie uniquement Toutes Supervision OUI NON Description Apprendre Signal radio IN OUT Filaires tat Activ D sactiv Polarit ON OFF 12 V activ e 0 V activ e SIR NE 12 V al...

Page 29: ...PXWDTPI Alarme Capteur PXWIRCE Alarme Capteur PXWDTVE Alarme Capteur PXWDTCL Alarme Capteur PXWIRCB Entr e 1 Entr e 2 Alarme Capteur PXWCOB01 PXWCOM01 Entr e 1 Entr e 2 Contact REED PXWDTCB PXWDTCM E...

Page 30: ...tie s lec tionn e changera d tat chaque enfoncement de la touche tat par d faut ACTIV s il est appris D SACTIV s il n est pas appris S lectionner la radiocommande configurer 1 8 et en d finir l tat AC...

Page 31: ...d activation entr e ou de d sactivation sortie de l installation tat par d faut ACTIV E si elle est apprise D SACTIV E si elle n est pas apprise Permet de g rer ou non la sortie de la sir ne radio AC...

Page 32: ...d lai configur dans le menu CONFIGURAT T R INITIA ex contact volet roulant capteurs volum triques etc Pour configurer les v nements d alarme voir le manuel du dispositif distant Ces v nements seront r...

Page 33: ...10 Configurations Contraste afficheur Visual m pan par d faut OUI Permet d activer ou de d sactiver la visualisation de la m moire des pannes Visualiser m moire pannes Visualis pannes par d faut OUI P...

Page 34: ...lisat par d faut 123456 Permet de modifier le code d acc s de l utilisateur Codes Utilisateur Code install par d faut 222222 Permet de modifier le propre code d acc s L installateur peut galement modi...

Page 35: ...la saisie du code utilisateur Visualiser m moire alarmes Visual alarmes Permet d activer ou de d sactiver la visualisation de la derni re alarme d tec t e par le syst me d alarme Les alarmes en cours...

Page 36: ...ite en fin de journ e Horloge Code utilisat Permet de modifier le code d acc s de l utilisateur Codes Codes Utilisateur Buzzer activ Permet d activer ou de d sactiver les signaux sonores des touches d...

Page 37: ...FA00772 RU PXWRXU...

Page 38: ...2 FA00772 RU 1 05 2017 CAME S p A 123456 222222 32 8 1 8 123456 222222...

Page 39: ...3 FA00772 RU 1 05 2017 CAME S p A 1 3 1 8 1 8 1 15 12 0 12 0 1 254...

Page 40: ...4 FA00772 RU 1 05 2017 CAME S p A 24 1 3 1 8 1 15 1 8 12 0 12 0 10 90 1 60 1 254 1 254 1 254 0 254...

Page 41: ...5 FA00772 RU 1 05 2017 CAME S p A S 1 1 4 2 5 8 3 9 12 1 1 2 3 PXWIR01 PXWDT PXWDTPI PXWIRCE PXWDTVE PXWDTCL PXWIRCB 1 2 PXWCOB01 PXWCOM01 1 2 REED PXWDTCB PXWDTCM 1 2 24 1 32...

Page 42: ...6 FA00772 RU 1 05 2017 CAME S p A 3 8 1 8 1 6 0 WL 1 WL 3 WL 5...

Page 43: ...7 FA00772 RU 1 05 2017 CAME S p A S 1 6 0 WL 1 WL 3 WL 5...

Page 44: ...8 FA00772 RU 1 05 2017 CAME S p A NC CI 12 12 1 8 1 6 0 WL 1 WL 3 WL 5...

Page 45: ...9 FA00772 RU 1 05 2017 CAME S p A 20 5 60 10 90 10 30...

Page 46: ...10 FA00772 RU 1 05 2017 CAME S p A 123456 222222 1 2 3 0 10...

Page 47: ...11 FA00772 RU 1 05 2017 CAME S p A 2 2 10 90 1 60 123456...

Page 48: ...Della Libert 15 Via Cornia 1 b 1 c 31030 Dosson di Casier Treviso Italy 33079 Sesto al Reghena Pordenone Italy 39 0422 4940 39 0422 4941 39 0434 698111 39 0434 698434 www came com FA00772 RU 1 05 201...

Reviews: