4.1 Turnstile 

4 Description

2.1 Intended use 

1 Legend of symbols

 This symbol shows parts to be read carefully.

 This symbol shows parts related to safety.

 This symbol shows what to tell users.

2 Intended use and limits

The TWISTER electromechanical turnstile is designed to select transit flows in high-volume passage areas, and in highly fre-
quented contexts like stadiums, airports, stations, public buildings and in any other places where high-volume flows need to be 
regulated and/or selected

 Any installation or use other than that shown in this manual is prohibited.

3 Reference Legislation

IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION

WARNING: WRONG INSTALLATION MAY CAUSE SERIOUS INJURY, FOLLOW ALL INSTALLATION INSTRUCTIONS

THIS MANUAL IS EXCLUSIVELY MEANT FOR PROFESSIONAL INSTALLERS OR OTHER COMPETENT PERSONS

This product is designed and built by CAME Cancelli Automatici S.p.A. in compliance with the current safety legislation. 

Selective, bidirectional, electromechanical turnstile, entirely made of AISI 304 stainless steel with “scotch-brite” fi nish, fi tted with 
a removable top cover with key lock, and removable side legs. The aluminium tripod head bears a shiny fi nish and stainless steel, 
shiny-polished arms. 

It allows passage in the desired direction of one person a time. By activating a command device, the mechanism releases the tripod 
which rotates freely allowing people to pass through; the arms automatically return into place and the mechanism locks immediately 
after a single passage, waiting for a new command.

The range includes:

001PST003 - Bi-directional electromechanical tripod turnstile AISI 304 steel with scotch-brite fi nishing, complete with ocntrol board, 
transponder sensors and high-luminosity LED bi-directional traffi c light with display, anti-climb system. Tripod automatic release in 
case of blackout.

Power: 230 V AC 50 / 60 Hz
Power Draw: 260 mA max
Insulation class: II
Protection rating: IP44
Weight: 60 Kg

The product being described herein complies with the following legislation: see compliance statement.

4.2 Technical Data

Summary of Contents for PST003

Page 1: ...PST003 TWISTER SERIES TRIPOD TURNSTILE English EN INSTALLATION MANUAL 342EN...

Page 2: ...pletely visible If missing ap ply a permanent label that shows the position of the release mechanism Before delivering to the client verify that the system is EN 12453 impact test standard compliant M...

Page 3: ...THIS PAGE LEFT INTENTIONALLY BLANK THIS PAGE LEFT INTENTIONALLY BLANK...

Page 4: ...OR OTHER COMPETENT PERSONS This product is designed and built by CAME Cancelli Automatici S p A in compliance with the current safety legislation Selective bidirectional electromechanical turnstile e...

Page 5: ...to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH Legs 1 Tripod 2 Steel body 3 Casing 4 Casing cover 5 Upper cover 6 Traffic light 7 Status displa...

Page 6: ...erform the installation in full compliance of the current legislation 6 1 Preliminary checks Before installing the automated device please Set up a proper omnipolar cut off device with contacts more t...

Page 7: ...ffic light with display 2 Electric wiring connector block 3 protection handrail 4 Status displays 5 6 3 Standar installation 6 4 Setting up the turnstile Warning installation required two people Use h...

Page 8: ...ici s p a to notify users ENGLISH 3 Remove the top cover N B Lift the cover slightly tor easy removal 4 Remove the two screws that fix the casing to the legs 5 Remove the protective casings by gently...

Page 9: ...the central hole Screw the turnstile to the ground using the ratchet spanner 6 5 Preparing the site and fixing the turnstile to the ground 1 Check that the floor where the turnstile is anchored is lev...

Page 10: ...through a cable gland at the bottom of the turnstile leg Earth Cable clamps Hole Hole 7 1 Cable types and sections N B If the cable length differs to that shown in the table determine cable section ba...

Page 11: ...ection terminal board 8 Buzzer Siren connection terminal 9 Transponder connection terminals option 10 R700 board connectors 11 Memory roll board connectors 12 Traffic light display connection terminal...

Page 12: ...ontact Release the tripod in a clockwise direction If no other command is given the turnstile relocks it self automatically after the time set in the F5 function RBM84 Access control Software for reco...

Page 13: ...lockwise activated trasponder N O contact Release the tripod in a clockwise direction If no other com mand is given the turnstile relocks itself automatically after the time set in the F5 function Cou...

Page 14: ...load any settings including registered users on another board The R700 and Memory Roll boards must be inserted when the power is disconnected Once the power is connected wait 10 seconds before procee...

Page 15: ...ng Display to view the functions and settings that are assigned via pro gramming buttons or transponder 10 2 Menu structure Creating the MASTER card Creating a new card Cancelling a card Cancelling al...

Page 16: ...pages 14 and 15 o Function 2 Creating a new card Creating new cards max 500 cards See detailed fucntions on page 16 Function 3 Cancelling a card Select the number of the pass that has to be cancelled...

Page 17: ...ages OFF Note the number appearing on the display shows user presence at the entrance at that moment Function 9 setting the time and date Note press the ENTER button until the datum you wish to change...

Page 18: ...ore conse cutive accesses to the same area for example in a gym to prevent clients entering with the personal pass of a client who is already inside Funzione 16 Data recording in the memory roll It sa...

Page 19: ...he arrows then press ENTER then press ENTER to confirm also for the the sub menus move by using the arrows to raise or lower a value Open the turnstile s upper cover and position it turned by 90 abo v...

Page 20: ...sing and programming the menu using the Master card 1 To enter the function menu place the Master pass on the transponder TSP1 The display will show F1 The transponder remains green throughout the pro...

Page 21: ...er TSP1 to enter the F 2 function 4 The transponder TSP2 led will start flashing red 10 7 Creating a new card using the Master 2 Place the Master pass on the transponder TSP2 The display will scroll t...

Page 22: ...ng to move it try to properly secure the turnstile to the ground because unstable securing can result in danger Do not clean the turnstile with products containing chemical agents that could damage th...

Page 23: ...by simply following these brief disposal instructions DISPOSING OF THE PACKAGING The packaging components cardboard plastic etc are considered solid urban waste and may disposed without any trouble in...

Page 24: ...ion Solutions Pvt Ltd Automation Solutions Pvt Ltd A 10 Green Park 110016 New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A 11345 NW 1...

Reviews: