7 Electrical wiring
Distribute the electrical cables (see table “Cable types and sections”) as illustrated in the picture below.
Running power cables through any accessori-
es through the plate hole at the bottom of the
turnstile leg.
Pre-drilled cable hole on the plate.
Running the power cable (alternatively to the plate
hole) through a cablegland in the bottom part of the
turnstile leg.
Cable gland
Hole
Hole
Power up the command board via the
power supply unit
Power supply
unit
24DC
7.1 Cable types and sections
N.B. If the cable length differs to that shown in the table, determine cable section based on the actual power draw by the connected
devices and according to what is prescribed by law CEI EN 60304-1.
For sequential connections on the same line, length-measurements by the table must be converted on the basis of draw and actual
distances. To connect any products not mentioned in this manual, see documentation provided with said products.
Connections
Cable types
Cable length
1 < 10 m
Cable length
10 < 20 m
Cable length
20 < 30 m
Power to electrical panel 230V
FROR CEI
20-22
CEI EN
50267-2-1
3G x 1,5 mm
2
3G x 1,5 mm
2
3G x 1,5 mm
2
Power to accessories
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 1 mm
2
Command and safety devices
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2