2 Description

Central server

This is the core of the system. The server hosts the software for access 
control and monitoring (even remotely) and VoIP control unit management 
software for the integrated phone system.

Automatic pay station

Unit for automatic payment that involves the following main functions:

- Reading and printing of tickets

- TAG RFID proximity card reading 

- TFT 15.4 ’ colour monitor also available in high brightness and touch 

versions.

- payment receipt

- payment in coins and notes, with ATM card and credit card (optional)

- change in coins (also available with note change option)

- barcode and QR-code reader also from smartphones

Exit unit

Exit unit that involves the following main functions:

- Ticket reading

- TAG RFID proximity card reading (ISO format)

- LCD TFT colour 5.7’ monitor

- barcode and QR-code reader also from smartphones (optional)

Entry unit

Entrance unit that involves the following main functions:

- ticket printing

- TAG RFID proximity card reading (ISO format)

- LCD TFT colour 5.7’ monitor

- barcode and QR-code reader also from smartphones (optional)

Manned pay station

Composed  of  an  industrial  computer  with  touch  screen  15’.  Depending  on 
your needs, the computer can be integrated with: manual ticket Barcode 
reader / built-in reader, ticket printer and reader, proximity and microchip 
ISO format plastic card writer / receipt printer / additional user-side display / 
RFID cards writer / cash drawer.

Two-sided "SPACES - FULL" lightbox sign.

Traffic light with red - green ø 200 mm lights.

Spaces display

Spaces available signage panel.

Bi-channel magnetic sensor to detect metal masses

Intercom station

Units installed within the local ethernet network: can only be intercom, or 
upon request, video-intercom.

Vehicle classifier

The system allows to automatically classify up to three classes of vehicles.

OCR video camera for reading number plates

The system allows you to read and recognise the license plates of incoming 
and outbound vehicles.

EYE SYSTEM cameras

The system allows to associate hi-res stills of all four sides of incoming and 
outbound vehicles.

UHF Long Range Antenna 

 

Automatic Identification System, of vehicles authorised access, via RFID UHF 
TAG.

Summary of Contents for PS ONE

Page 1: ...INSTALLATION MANUAL PS ONE PAY TO PARK CONTROL SYSTEM English EN 119GF88EN...

Page 2: ...diagram 3 2 Description 4 3 Technical specifications 5 4 Wiring diagram 7 5 Dimensions mm 8 6 Example of system layout with side by side entrance and exit lanes 10 7 Entrance unit exit unit card and...

Page 3: ...a space to station the vehicle in a convenient manner for taking a ticket We recommend a minimum distance of 2 8 m between the entrance unit and the barrier Provide for pedestrian transit lanes clearl...

Page 4: ...ance unit that involves the following main functions ticket printing TAG RFID proximity card reading ISO format LCD TFT colour 5 7 monitor barcode and QR code reader also from smartphones optional Man...

Page 5: ...Storage temperature 0 C 70 C Power supply 230 V 50 Hz 150 W Container Micro tower Microprocessor Dual Core 1 5 GHz AMD Turion II RAM PC3 10600E DDR 2GB HDD RAID 2 x 500GB SATA drivers Network control...

Page 6: ...grated system with ABS plastic adjustable monitor Display 15 TFT LCD panel 1024x768 w resistive touch screen Microprocessor Intel E5300 Pentium Dual Core 2 60 GHz RAM DDR2 512 MB HDD 500 GB Dimensions...

Page 7: ...ICLE DETECTION MAGNETIC loop VEHICLE DETECTION MAGNETIC loop Entrance unit Automatic pay station GSM router I O Interface Central server Intercom station Manned pay station ATM reader Receipt printer...

Page 8: ...4 CAME cancelli automatici s p a The data and information provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S p a ENGLISH 5 Overall dimensions...

Page 9: ...ME Cancelli Automatici S p a ENGLISH Automatic pay station The automatic pay station must be installed in a sheltered area protected from rain snow dust or other elements If necessary install elements...

Page 10: ...E Cancelli Automatici S p a ENGLISH 6 Example of system layout with side by side entrance and exit lanes Note the example shows the minimum dimensions in mm between the components of the system These...

Page 11: ...ection terminal 3 Fan and heater connection terminal 4 Barrier connection terminal 5 LED A Relay A active 6 LED B Relay B active 7 R700 optional card connection terminal 8 Paper sensor connection term...

Page 12: ...B IN1 Vehicle presence detection of loop 1 IN2 Vehicle on Safety loop located under the barrier IN3 Vehicle presence detection of loop 2 optional IN4 Vehicle Classifier Axle Detection Activation optio...

Page 13: ...ny time without prior notice by CAME Cancelli Automatici S p a ENGLISH 1 Ticket key 2 LCD Backlight 3 User keys 4 Ticket slit LED 5 Rfid Reader 6 Brightness sensor 7 Power supply and data input 8 Loud...

Page 14: ...ption 1 VAC power supply input 2 Interior lighting connection terminal 3 Fan and heater connection terminal 4 Remote alarm output terminal 5 Reset relay terminal 6 Power supply detector terminal 7 Pap...

Page 15: ...ompartment IN2 Middle door closed cash compartment IN3 Collection Drawer Fitted IN4 Coins Drawer Fitted IN5 Coins Drawer Engaged IN6 Vac power present LED index input on automatic pay station card USB...

Page 16: ...CCTALK address selection Dipswitch 6 CCTALK 5 Channel change return Hopper 1 connection 7 CCTALK 3 Channel connection available 8 CCTALK 2 Channel change return Hopper 2 connection 9 CCTALK 1 Channel...

Page 17: ...t any time without prior notice by CAME Cancelli Automatici S p a ENGLISH Automatic Pay Station Connections Board 1 Coin slot shutter 2 LCD Backlight 3 User keys 4 Ticket slit LED 5 Rfid Reader 6 Brig...

Page 18: ...with hooks at the end with a capacity of at least 250 kg in the seats on the head of the central element Use a mechanical arm to tension the steel cables and then lift the central element and bring i...

Page 19: ...in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S p a ENGLISH Position the top element above the central one and then secure the nine screws supplied...

Page 20: ...ween the two parts that make up the cabinet with the supplied cable Power from the main electrical panel of the site to provide adequate all pole disconnect device for disconnecting line voltage MCB R...

Page 21: ...hout prior notice by CAME Cancelli Automatici S p a ENGLISH Plug the power cables in the correct locations of the socket Fix the shell on the socket by tightening the respective fixing screws Inside t...

Page 22: ...es in the electrical panel located in the upper part of the cabinet 9 4 Switching on V AC service outlet 100 VA maximum load protected by S1 230V version only SWITCH DESCRIPTION S1 Input circuit break...

Page 23: ...ance Green Operation successful 9 6 Automatic Pay Station power supply wiring diagram Devices CPU and AUTOMATIC PAY STATION Additional heater Power supply 2 Large 24 V DC 9 6 A 230 W Reset command 24V...

Page 24: ...otruding bolts place the cabinet on the base and secure it Note Install the cabinet with the inspection door facing the easiest to reach direction Fill the hole with concrete and immerse the xing base...

Page 25: ...he container In the entry station remove the screw that secures the Roboticket printer or base printer 11 1 Vehicle detection loops connection Locate the two channel sensor on the left side of the uni...

Page 26: ...ier connection Access to the control board of the unit by removing the cover of the container Open command Close command From the connec tor of the open barrier gate LED Identify the connection to the...

Page 27: ...n connect the vehicle crossing loop On the unit control board locate the terminal to connect the SMA detector installed in the barrier and then make connections NB For installation and programming see...

Page 28: ...e to provide adequate all pole disconnect device for disconnecting line voltage MCB RCD Required characteristics Circuit breaker with breaking current up to 16 A 230 V or 25 A 120 V RCD with 30 mA sen...

Page 29: ...on provided in this manual are subject to change at any time without prior notice by CAME Cancelli Automatici S p a ENGLISH Plug the power cables in the correct locations of the socket Fix the shell o...

Page 30: ...6 ETHERNET connection 11 7 Switching on Inside the bottom section of the unit connect the Ethernet cable to its terminal After making all electrical connections switch on the entrance and exit unit by...

Page 31: ...hite Maintenance mode Flashing Red Out of Service Alarm Green Barrier opening Serial CPU and Accessories Traffic light connections Standard internal fans and heater Power supply AC DC PSONE V AC input...

Page 32: ...a l ngua PL Wszystkie inne informacje dotycz ce rmy produkt w oraz us ug i pomocy technicznej w Waszym j zyku znajduj si na stronie RU HU A v llalatra term keire s a m szaki szervizre vonatkoz minden...

Reviews: