CAME OPP001 Installation, Operation And Maintenance Manual Download Page 4

p. 

4

 - M

an

u

al

 

FA

0

1

0

8

6

-E

N

 - 0

2

/2

0

18 - © C

A

M

E S

.p.

A

. - "

Tr

an

sl

ate

d o

rig

in

al

 in

str

u

cti

on

s"

GENERAL PRECAUTIONS FOR INSTALLERS

 

WARNING! Important safety instructions.

Follow all of these instructions. Improper installation can cause serious bodily 

harm.

Before continuing, also read the general precautions for users.

T

HIS

 

PRODUCT

 

MUST

 

ONLY

 

BE

 

USED

 

FOR

 

ITS

 

SPECIFICALLY

 

INTENDED

 

PURPOSE

. A

NY

 

OTHER

 

USE

 

IS

 

DANGEROUS

C

AME

S.P.A.

IS

 

NOT

 

LIABLE

 

FOR

 

ANY

 

DAMAGE

 

CAUSED

 

BY

 

IMPROPER

WRONGFUL

 

AND

 

UNREASONABLE

 

USE

. • T

HIS

 

MANUAL

'

S

 

PRODUCT

 

IS

 

DEFINED

 

BY

 

MACHINERY

 

DIRECTIVE

 2006/42/CE 

AS

 "

PARTLY

-

COMPLETED

 

MACHINERY

". 

Q

UASI

-

COMPLETED

 

MACHINERY

 

IS

 P

ARTLY

-

COMPLETED

 

MACHINERY

 

IS

 

A

 

SET

 

THAT

 

ALMOST

 

CONSTITUTES

 

A

 

MACHINE

BUT

 

WHICH

ALONE

CANNOT

 

ENSURE

 

A

 

CLEARLY

 

DEFINED

 

APPLICATION

. P

ARTLY

-

COMPLETED

 

MACHINERY

 

IS

 

ONLY

 

DESTINED

 

TO

 

BE

 

INCORPORATED

 

OR

 

ASSEMBLED

 

TO

 

OTHER

 

MACHINERY

 

OR

 

OTHER

 

PARTLY

-

COMPLETED

 

MACHINERY

 

OR

 

APPARATUSES

 

TO

 

BUILD

 

MACHINERY

 

THAT

 

IS

 

REGULATED

 

BY

 D

IRECTIVE

 2006/42/CE. T

HE

 

FINAL

 

INSTALLATION

 

MUST

 

BE

 

COMPLIANT

 

WITH

 E

UROPEAN

 

DIRECTIVE

 2006/42/CE 

AND

 

CURRENT

 E

UROPEAN

 

REFERENCE

 

STANDARDS

G

IVEN

 

THESE

 

CONSIDERATIONS

ALL

 

PROCEDURES

 

STATED

 

IN

 

THIS

 

MANUAL

 

MUST

 

BE

 

EXCLUSIVELY

 

PERFORMED

 

BY

 

EXPERT

QUALIFIED

 

STAFF

. • T

HE

 

MANUFACTURER

 

DECLINES

 

ANY

 

LIABILITY

 

FOR

 

USING

 

NON

-

ORIGINAL

 

PRODUCTS

WHICH

 

WOULD

 

RESULT

 

IN

 

WARRANTY

 

LOSS

 • K

EEP

 

THIS

 

MANUAL

 

INSIDE

 

THE

 

TECHNICAL

 

FOLDER

 

ALONG

 

WITH

 

THE

 

MANUALS

 

OF

 

ALL

 

THE

 

OTHER

 

DEVICES

 

USED

 

FOR

 

YOUR

 

AUTOMATION

 

SYSTEM

. • C

HECK

 

THAT

 

THE

 

TEMPERATURE

 

RANGE

 

SHOWN

 

ON

 

THE

 

OPERATOR

 

IS

 

SUITABLE

 

TO

 

THE

 

LOCATIONS

 

WHERE

 

IT

 

WILL

 

BE

 

INSTALLED

. • L

AYING

 

THE

 

CABLES

INSTALLATION

 

AND

 

TESTING

 

MUST

 

FOLLOW

 

STATE

-

OF

-

THE

-

ART

 

PROCEDURES

 

AS

 

DICTATED

 

BY

 

REGULATIONS

 

• I

F

 

THE

 

POWER

-

SUPPLY

 

CABLE

 

IS

 

DAMAGED

IT

 

MUST

 

BE

 

IMMEDIATELY

 

REPLACED

 

BY

 

THE

 

MANUFACTURER

 

OR

 

BY

 

AN

 

AUTHORIZED

 

TECHNICAL

 

ASSISTANCE

 

CENTER

OR

 

IN

 

ANY

 

CASE

BY

 

QUALIFIED

 

STAFF

TO

 

PREVENT

 

ANY

 

RISK

 • D

U

-

RING

 

ALL

 

PHASES

 

OF

 

THE

 

INSTALLATION

 

MAKE

 

SURE

 

YOU

 

HAVE

 

CUT

 

OFF

 

THE

 

MAINS

 

POWER

 

SOURCE

. • T

HE

 

OPERA

-

TOR

 

CANNOT

 

BE

 

USED

 

WITH

 

GATES

 

FITTED

 

WITH

 

PEDESTRIAN

 

DOORS

UNLESS

 

ITS

 

OPERATION

 

CAN

 

BE

 

ACTIVATED

 

ONLY

 

WHEN

 

THE

 

PEDESTRIAN

 

DOOR

 

IS

 

IN

 

SAFETY

 

POSITION

. • M

AKE

 

SURE

 

THAT

 

PEOPLE

 

ARE

 

NOT

 

ENTRAPPED

 

BETWEEN

 

THE

 

GATE

'

S

 

MOVING

 

AND

 

FIXED

 

PARTS

 

DUE

 

TO

 

THE

 

GATE

'

S

 

MOVEMENT

. B

EFORE

 

INSTALLING

 

THE

 

OPERATOR

CHECK

 

THAT

 

THE

 

GATE

 

IS

 

IN

 

PROPER

 

MECHANICAL

 

CONDITION

THAT

 

IT

 

IS

 

PROPERLY

 

BALANCED

 

AND

 

THAT

 

IT

 

PROPERLY

 

CLO

-

SES

IF

 

ANY

 

OF

 

THESE

 

CONDITIONS

 

ARE

 

NOT

 

MET

DO

 

NOT

 

CONTINUE

 

BEFORE

 

HAVING

 

MET

 

ALL

 

SAFETY

 

REQUIREMEN

-

TS

. • M

AKE

 

SURE

 

THAT

 

OPENING

 

AND

 

CLOSING

 

LIMITERS

 

ARE

 

FITTED

 • M

AKE

 

SURE

 

THE

 

OPERATOR

 

IS

 

INSTALLED

 

ONTO

 

A

 

STURDY

 

SURFACE

 

THAT

 

IS

 

PROTECTED

 

FROM

 

ANY

 

COLLISIONS

 • M

AKE

 

SURE

 

THAT

 

MECHANICAL

 

STOPS

 

ARE

 

ALREADY

 

INSTALLED

 • I

F

 

THE

 

OPERATOR

 

IS

 

INSTALLED

 

LOWER

 

THAN

 2.5 

FROM

 

THE

 

GROUND

 

OR

 

FROM

 

ANY

 

OTHER

 

ACCESS

 

LEVEL

FIT

 

ANY

 

PROTECTIONS

 

AND

 

SIGNS

 

TO

 

PREVENT

 

HAZARDOUS

 

SITUATIONS

. • D

O

 

NOT

 

FIT

 

THE

 

OPERA

-

TOR

 

UPSIDE

 

DOWN

 

OR

 

ONTO

 

ELEMENTS

 

THAT

 

COULD

 

YIELD

 

TO

 

ITS

 

WEIGHT

. I

F

 

NECESSARY

ADD

 

REINFORCEMENTS

 

TO

 

THE

 

FASTENING

 

POINTS

 • D

O

 

NOT

 

INSTALL

 

DOOR

 

OR

 

GATE

 

LEAVES

 

ON

 

TILTED

 

SURFACES

 • C

HECK

 

THAT

 

NO

 

LAWN

 

WATERING

 

DEVICES

 

SPRAY

 

THE

 

OPERATOR

 

WITH

 

WATER

 

FROM

 

THE

 

BOTTOM

 

UP

. • A

NY

 

RESIDUAL

 

RISKS

 

MUST

 

BE

 

INDICATED

 

CLEARLY

 

WITH

 

PROPER

 

SIGNAGE

 

AFFIXED

 

IN

 

VISIBLE

 

AREAS

. A

LL

 

OF

 

WHICH

 

MUST

 

BE

 

EXPLAINED

 

TO

 

END

 

USERS

. • S

UITABLY

 

SECTION

 

OFF

 

AND

 

DEMARCATE

 

THE

 

ENTIRE

 

INSTALLATION

 

SITE

 

TO

 

PREVENT

 

UNAUTHORIZED

 

PERSONS

 

FROM

 

ENTERING

 

THE

 

AREA

ESPECIALLY

 

MINORS

 

AND

 

CHILDREN

. • A

FFIX

 

CAUTIONARY

 

SIGNS

SUCH

 

AS

 

THE

 

DOOR

 

PLATE

THE

 

GATE

 

PLATE

WHEREVER

 

NEEDED

 

AND

 

IN

 

PLAIN

 

SIGHT

. • U

SE

 

PROPER

 

PROTECTIONS

 

TO

 

PREVENT

 

MECHANICAL

 

HAZARDS

 

WHEN

 

PEOPLE

 

ARE

 

LOITERING

 

AROUND

 

THE

 

MACHINERY

'

S

 

RANGE

 

OF

 

ACTION

FOR

 

EXAMPLE

 

AVOID

 

CRUSHING

 

OF

 

FINGERS

 

BETWEEN

 

THE

 

DRIVE

 

SHAFT

 

AND

 

THE

 

MECHANICAL

 

STOPS

AVOID

 

CRUSHING

 

WHEN

 

THE

 

GATE

 

IS

 

OPENING

 • T

HE

 

ELECTRICAL

 

CABLES

 

MUST

 

RUN

 

THROUGH

 

THE

 

CABLE

 

GLANDS

 

AND

 

NOT

 

TOUCH

 

ANY

 

PARTS

 

THAT

 

MAY

 

OVERHEAT

SUCH

 

AS

 

THE

 

MOTOR

TRANSFORMER

AND

 

SO

 

ON

 • S

ET

 

UP

 

A

 

SUITABLE

 

DUAL

 

POLE

 

CUT

 

OFF

 

DEVICE

 

ALONG

 

THE

 

POWER

 

SUPPLY

 

THAT

 

IS

 

COMPLIANT

 

WITH

 

THE

 

INSTALLATION

 

RULES

. I

T

 

SHOULD

 

COMPLETELY

 

CUT

 

OFF

 

THE

 

POWER

 

SUPPLY

 

ACCORDING

 

TO

 

CATEGORY

 III 

SURCHARGE

 

CONDITIONS

 • A

LL

 

OPENING

 

CONTROLS

 

MUST

 

BE

 

INSTALLED

 

AT

 

LEAST

 1.85 

M

 

FROM

 

THE

 

PERIMETER

 

OF

 

THE

 

GATE

'

S

 

WORKING

 

AREA

OR

 

WHERE

 

THEY

 

CANNOT

 

BE

 

REACHED

 

FROM

 

OUTSIDE

 

THE

 

GATE

. • A

LL

 

SWITCHES

 

IN

 

MAINTAINED

 

ACTION

 

MODE

 

MUST

 

BE

 

POSITIONED

 

SO

 

THAT

 

THE

 

MOVING

 

GATES

 

LEAVES

THE

 

TRANSIT

 

AREAS

 

AND

 

VEHICLE

 

THRU

-

WAYS

 

ARE

 

COMPLETELY

 

VISIBLE

AND

 

YET

 

THE

 

SWITCHES

 

MUST

 

BE

 

ALSO

 

AWAY

 

FROM

 

ANY

 

MOVING

 

PARTS

 • U

NLESS

 

THE

 

ACTION

 

IS

 

KEY

 

OPERATED

THE

 

CONTROL

 

DEVICES

 

MUST

 

BE

 

FITTED

 

AT

AT

 

LEAST

, 1.5 

M

 

FROM

 

THE

 

GROUND

 

AND

 

MUST

 

NOT

 

BE

 

ACCESSIBLE

 

TO

 

THE

 

PUBLIC

. • 

T

O

 

PASS

 

THE

 

COLLISION

 

FORCE

 

TEST

 

USE

 

A

 

SUITABLE

 

SENSITIVE

 

SAFETY

-

EDGE

. I

NSTALL

 

IT

 

PROPERLY

 

AND

 

ADJUST

 

AS

 

NEEDED

. • B

EFORE

 

HANDING

 

OVER

 

TO

 

USERS

CHECK

 

THAT

 

THE

 

SYSTEM

 

IS

 

COMPLIANT

 

WITH

 

THE

 2006/42/CE 

UNIFORMED

 M

ACHINERY

 D

IRECTIVE

. M

AKE

 

SURE

 

THE

 

SETTINGS

 

ON

 

THE

 

OPERATOR

 

ARE

 

ALL

 

SUITABLE

 

AND

 

THAT

 

ANY

 

SAFETY

 

AND

 

PROTECTION

 

DEVICES

AND

 

ALSO

 

THE

 

MANUAL

 

RELEASE

WORK

 

PROPERLY

. • A

FFIX

 

A

 

PERMANENT

 

TAG

THAT

 

DESCRIBES

 

HOW

 

TO

 

USE

 

THE

 

MANUAL

 

RELEASE

 

MECHANISM

CLOSE

 

TO

 

THE

 

MECHANISM

. • M

AKE

 

SURE

 

TO

 

HAND

 

OVER

 

TO

 

THE

 

END

 

USER

ALL

 

OPERATING

 

MANUALS

 

FOR

 

THE

 

PRODUCTS

 

THAT

 

MAKE

 

UP

 

THE

 

FINAL

 

MACHINERY

.

Summary of Contents for OPP001

Page 1: ...Gear motor for swing gates OPP series OPP001 INSTALLATION OPERATION AND MAINTENANCE MANUAL EN English FA01086 EN...

Page 2: ...g Check that there are no ob structions in the photocells area of operation If the problem cannot be solved by following the fixes in the table or if any malfunctions anomalies noises vibrations or su...

Page 3: ...p 3 Manual FA01086 EN 02 2018 CAME S p A Translated original instructions...

Page 4: ...MITERS ARE FITTED MAKE SURE THE OPERATOR IS INSTALLED ONTO A STURDY SURFACE THAT IS PROTECTED FROM ANY COLLISIONS MAKE SURE THAT MECHANICAL STOPS ARE ALREADY INSTALLED IF THE OPERATOR IS INSTALLED LOW...

Page 5: ...5 Manual FA01086 EN 02 2018 CAME S p A Translated original instructions Danger of high voltage Danger of foot crushing Danger of hand entrapment THE NEXT FIGURE SHOWS THE MAIN HAZARD POINTS FOR PEOPL...

Page 6: ...s and apartment blocks Any installation other than what is detailed in this manual is prohibited LIMITS TO USE Type OPP001 Maximum gate leaf length m 1 1 7 2 2 Maximum gate leaf weight kg 250 225 200...

Page 7: ...Manual FA01086 EN 02 2018 CAME S p A Translated original instructions DESCRIPTION OF PARTS 1 Gear motor 2 Gate bracket and fastening screw 3 Post bracket and fastening screw 4 Bushing for post bracket...

Page 8: ...opening and closing mechanical gate stops make sure that the point where the gearmotor is fastened is protected from any impacts and that the surface is solid enough set up suitable tubes and conduits...

Page 9: ...pliant For power supplies up to 48 V you can use FROR 20 22 II type cables that comply with EN 50267 2 1 CEI To connect the antenna use the RG58 we suggest up to 5 m For paired connection and CRP use...

Page 10: ...he gate leaf s opening angle the slower the opening speed and the greater is the gearmotor s thrust INSTALLATION The following illustrations are mere examples in that the space for anchoring the opera...

Page 11: ...on the post bracket Fasten the joint to the post bracket using the M8 x 35 bolt and UNI 7474 M8 nut Fasten the bracket to the post using suitable anchors and screws If the post is made of metal the b...

Page 12: ...ore establishing the endstop points you need to release the gearmotor see paragraph on manually releasing it and remove covers 1 and 2 while carefully following the illustrations Open the gate leaf th...

Page 13: ...ate leaf completely and rest it against the mechanical stop using the slide guide Fasten the closing mechanical stop s grub screws For opening Reach the gate leaf opening point you want and take the m...

Page 14: ...otas A and B Cut and fasten post bracket by supplementing it with an additional bracket b not issued Open the gate max 90 establish the quota E and establish the gate bracket fastening point Fasten th...

Page 15: ...then snap them down into place FINAL OPERATIONS FASTENING THE COVERS Once you have completed all electrical connections and commissioning fit the covers as shown here Gearmotor with encoder M2 24 V D...

Page 16: ...s DISPOSING OF THE PACKAGING The packaging materials cardboard plastic and so on should be disposed of as solid household waste and simply separated from other waste for recycling Always make sure you...

Reviews: