background image

PARAMETER

USER ACTIONS

FACTORY SETTING LED STATUS

Unlock

Press

UNLOCK

button (3)

0000

The LED flashes slowly to indicate that an

Then type in your four-figure pin number using 

NUMBER

buttons

0-9

(1).

adjustment session is under way.

The first time you adjust your sensor

*

, enter the factory value code (0000).

Sensitivity

Press the 

SENSIVITY

button (6).

7

The LED flashes more rapidly while the unit waits

Use

NUMBER

buttons

0-9

(1) to enter the sensitivity coefficient you want or

for the corresponding numerical value.

adjust this coefficient using the 

PLUS

(2) or 

MINUS

(4) buttons. 

It then continues to flash more slowly.

Repeat this operation to change the sensitivity again.

Hold time 

Press the 

HOLD TIME 

button (5) and use 

NUMBER

buttons

0-9

(1) to enter

0,5 seconds

The LED flashes more rapidly while the unit waits

the required hold time (up to 9 seconds).

for the corresponding numerical value.
It then continues to flash more slowly.

Detection mode

Press the 

DETECTION MODE 

button (7).  

unidirectional

The LED flashes more rapidly while the unit waits

(EAGLE 1 only)

Use 

NUMBER

buttons

1-3

(1) to select the required mode : 

for EAGLE 1

for the corresponding numerical value.

button 1 : bidirectional mode                                                                       with MTF function

It then continues to flash more slowly.

2 : unidirectional mode

bidirectional

3 : unidirectional mode with MTF function

for EAGLE 2

Relay

Press the 

RELAY CONFIGURATION 

button (11) and use 

NUMBER

buttons

1-4

(1)

active output

The LED flashes more rapidly while the unit waits 

configuration

to select the required relay configuration :

for the corresponding numerical value.

button 1 : active output, relay contact closed during detection, 

It then continues to flash more slowly.

open during non-detection

2 : passive output, relay contact open during detection, 

closed during non-detection

3  : continuous detection, relay contact always closed
4 : continuous non-detection, relay contact always open 

Immunity

Press the 

IMMUNITY

button (8).

Normal

The LED flashes more rapidly while the unit waits

Use

NUMBER

buttons

1-3

(1) to select the type of digital filter required :

for the corresponding numerical value.

button 1 : detection of quasi-presence

It then continues to flash more slowly.

2 : norma
3 : increased immunity

Lock

When all the parameters have been recorded, press the 

LOCK

button (10).

0000

The LED stops flashing to return to its normal

If you wish to enter a new access code, use 

NUMBER

keys

0-9

to enter the new

function.

four-figure code within 10 seconds.  It must begin with 1.
If you want to keep the current access code, press a second time the 

LOCK

button (10).

PARAMETERS

USER ACTIONS 

Check values

Press the button for the parameter whose value you wish to check (button 5, 6, 7, 8, 11), then press the 

CHECK VALUES

button

(9)

.  Then simply count the number of times the LED flashes.  This corresponds to the status of the parameter in 

question.  Repeat the operation to find out the status of the other parameters.  

eg : 

detection mode button - 2 flashes
the parameter is set in unidirectional mode

sensitivity button - 6 flashes
the parameter is set at 6

PARAMETERS

USER ACTIONS 

Default

Press the 

DEFAULT VALUE 

button

(

12

),

then press the number button 1. All the parameters are reset to their factory values.

In case of high mounting, the sensor can be configured in order to be more sensitive : 

before adjusting the sensor

, press the 

DEFAULT VALUE

button (12).

Then press the number button 

2

.  All the parameters are reset to their factory values but the sensor has now an increased sensitivity scale.  Then adjust the

other parameters.
Should you come back to the standard sensitivity scale, repeat the procedure with the 

DEFAULT VALUE

button followed by 

1

.

* Note : when your access code is reset to the factory value (0000) you can access adjustment mode directly without the

need to re-enter this code.

When the remote-controlled configuration of the sensor is complete, you can find out the values entered for the 
parameters at any time in the following way :

When the remote-controlled configuration of the sensor is complete, you can reset all the parameters to their factory values
by means of the following procedure :

7

All data checked with the maximum care. However, no liability is accepted for any error or omission. The declaration de conformity and other technical documentation 
are available on our website www.came.it - BUY-TO-SELL PRODUCT 

M

an

u

al

 c

od

e: 

1

1

9

P

M

8

9

11

9

P

M

8

9

 ve

r.

 

1

.0

1.

0

  1

1/2

0

0

9  - 

42.7228

 - MR

T001 - REMOTE CONTROL CAME - MUL

TI 

Reviews: